Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fusion Algorithm in Magnetic Resonance/Positron Emission Tomography using Attenuation Correction based on Ultrashort Echo-Time Pulse Sequences

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Chanrok-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2024-06-14T12:30:31Z-
dc.date.available2024-06-14T12:30:31Z-
dc.date.issued2024-03-
dc.identifier.issn1226-1750-
dc.identifier.issn2233-6656-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/91519-
dc.description.abstractPositron emission tomography (PET) images in magnetic resonance (MR)/PET fusion imaging systems are corrected for parts attenuated by gamma-rays by various MR pulse sequences. We aimed to study the quality of MR/PET images using an attenuation correction method based on ultrashort echo-time (UTE) pulse sequences. The proposed image-quality improvement algorithm was modeled as a convergence of the median-modified Wiener filter (MMWF) for noise reduction and Prewitt operator for emphasizing the edge area. By applying the proposed algorithm to MR/PET images, superior contrast to noise ratio and coefficient of variation values were obtained compared to those in the original image. The edge rise distance data of the proposed algorithm exhibited a very small difference from that of the original MR/PET image (difference: 2.21 %). In conclusion, we confirmed the applicability and usefulness of MMWF and Prewitt operator in UTE-based MR/PET imaging.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN MAGNETICS SOC-
dc.titleFusion Algorithm in Magnetic Resonance/Positron Emission Tomography using Attenuation Correction based on Ultrashort Echo-Time Pulse Sequences-
dc.typeArticle-
dc.identifier.wosid001199406200015-
dc.identifier.doi10.4283/JMAG.2024.29.1.117-
dc.identifier.bibliographicCitationJOURNAL OF MAGNETICS, v.29, no.1, pp 117 - 122-
dc.identifier.kciidART003063673-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85193614701-
dc.citation.endPage122-
dc.citation.startPage117-
dc.citation.titleJOURNAL OF MAGNETICS-
dc.citation.volume29-
dc.citation.number1-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthormagnetic resonance/positron emission tomography fusion image-
dc.subject.keywordAuthorultrashort echo-time pulse sequence-
dc.subject.keywordAuthorconvergence algorithm using median-modified Wiener filter and prewitt operator-
dc.subject.keywordAuthorevaluation of image quality-
dc.subject.keywordPlusMODIFIED WIENER FILTER-
dc.subject.keywordPlusIMAGE QUALITY-
dc.subject.keywordPlusPET-
dc.subject.keywordPlusMRI-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE