Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Noise Level and Blind Quality Evaluations in Abdominopelvic Electromagnetic X-ray Computed Tomographic Images using Deep-learning Reconstruction Method

Full metadata record
DC Field Value Language
dc.contributor.authorShim, Jina-
dc.contributor.authorLee, Seungwan-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2024-06-19T13:00:22Z-
dc.date.available2024-06-19T13:00:22Z-
dc.date.issued2024-03-
dc.identifier.issn1226-1750-
dc.identifier.issn2233-6656-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/91566-
dc.description.abstractThis study aimed to confirm the characteristics of deep-learning image reconstruction (DLIR) intensity in abdominopelvic computed tomography (CT) using noise level and blind quality evaluation parameters. The study was conducted using phantoms and patients, and CT images were obtained while adjusting the intensity of DLIR to low (DLIR-L), middle (DLIR-M), and high (DLIR-H). To quantitatively evaluate image quality, the coefficient of variation (COV) and contrast-to-noise ratio (CNR), as well as natural image quality evaluation (NIQE) and blind/referenceless image spatial quality evaluator (BRISQUE), were used. In both the noise level and blind quality evaluation results, a higher strength of DLIR resulted in better results derived from the phantom and patient studies. In particular, the results of the phantom study confirmed that NIQE and BRISQUE of CT images acquired using DLIR-H were improved by approximately 5 % and 1 %, respectively, compared to the corresponding the application of DLIR-L. Moreover, when high-strength deep-learning was applied to a real patient's CT image reconstruction method, the NIQE and BRISQUE results improved by approximately 6 % and 4 %, respectively, compared with their respective medium levels. In conclusion, we quantitatively analyzed the image quality according to the intensity of the recently developed deep-learning-based CT image reconstruction method.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN MAGNETICS SOC-
dc.titleNoise Level and Blind Quality Evaluations in Abdominopelvic Electromagnetic X-ray Computed Tomographic Images using Deep-learning Reconstruction Method-
dc.typeArticle-
dc.identifier.wosid001199406200008-
dc.identifier.doi10.4283/JMAG.2024.29.1.63-
dc.identifier.bibliographicCitationJOURNAL OF MAGNETICS, v.29, no.1, pp 63 - 70-
dc.identifier.kciidART003063587-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85193629252-
dc.citation.endPage70-
dc.citation.startPage63-
dc.citation.titleJOURNAL OF MAGNETICS-
dc.citation.volume29-
dc.citation.number1-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthorAbdominopelvic computed tomography (CT)-
dc.subject.keywordAuthorDeep-learning image reconstruction (DLIR) intensity-
dc.subject.keywordAuthorNoise level evaluation-
dc.subject.keywordAuthorBlind image quality evaluation-
dc.subject.keywordPlusSTATISTICAL ITERATIVE RECONSTRUCTION-
dc.subject.keywordPlusFILTERED BACK-PROJECTION-
dc.subject.keywordPlusOF-THE-ART-
dc.subject.keywordPlusABDOMINAL CT-
dc.subject.keywordPlusDOSE REDUCTION-
dc.subject.keywordPlusPHANTOM-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE