Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters : A Pilot Study

Full metadata record
DC Field Value Language
dc.contributor.author박보민-
dc.contributor.author서유진-
dc.contributor.author강성현-
dc.contributor.author심지나-
dc.contributor.author김하진-
dc.contributor.author임세원-
dc.contributor.author이영진-
dc.date.accessioned2024-07-21T03:00:56Z-
dc.date.available2024-07-21T03:00:56Z-
dc.date.issued2024-06-
dc.identifier.issn2288-3509-
dc.identifier.issn2384-1168-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/92034-
dc.description.abstractAdvanced modeled iterative reconstruction (ADMIRE) represents a repetitive reconstruction method that can adjust strength and kernel, each of which are known to affect computed tomography (CT) image quality. The aim of this study was to quantitatively analyze the noise and spatial resolution of CT images according to ADMIRE control factors. Patient im- ages were obtained by applying ADMIRE strength 2 and 3, and kernel B40 and B59. For quantitative evaluations, the noise level, spatial resolution, and overall image quality were measured using coefficient of variation (COV), edge rise distance (ERD), and natural image quality evaluation (NIQE). The superior values for the average COV, ERD, and NIQE results were obtained for the ADMIRE reconstruction conditions of ADMIRE 2 + B40, ADMIRE 3 + B59, and ADMIRE3 + B59. NIQE, which represents the overall image quality based on no-reference, was about 6.04 when using ADMIRE 3 + B59, showing the best result among the reconstructed image acquisition conditions. The results of this study indicate that the ADMIRE strength and kernel chosen for use in ADMIRE reconstruction have a significant impact on CT image quality. This highlights the importance of adjusting to the control factors in consideration of the clinical environment.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisher대한방사선과학회-
dc.titleEvaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters : A Pilot Study-
dc.typeArticle-
dc.identifier.bibliographicCitation방사선기술과학, v.47, no.3, pp 175 - 182-
dc.identifier.kciidART003093082-
dc.description.isOpenAccessN-
dc.citation.endPage182-
dc.citation.startPage175-
dc.citation.title방사선기술과학-
dc.citation.volume47-
dc.citation.number3-
dc.publisher.location대한민국-
dc.subject.keywordAuthorComputed tomography-
dc.subject.keywordAuthorAdvanced modeled iterative reconstruction (ADMIRE)-
dc.subject.keywordAuthorIteration intensity and kernel-
dc.subject.keywordAuthorNoise level and spatial resolution evaluations-
dc.subject.keywordAuthorBlind image quality evaluation-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE