Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters : A Pilot Study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박보민 | - |
dc.contributor.author | 서유진 | - |
dc.contributor.author | 강성현 | - |
dc.contributor.author | 심지나 | - |
dc.contributor.author | 김하진 | - |
dc.contributor.author | 임세원 | - |
dc.contributor.author | 이영진 | - |
dc.date.accessioned | 2024-07-21T03:00:56Z | - |
dc.date.available | 2024-07-21T03:00:56Z | - |
dc.date.issued | 2024-06 | - |
dc.identifier.issn | 2288-3509 | - |
dc.identifier.issn | 2384-1168 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/92034 | - |
dc.description.abstract | Advanced modeled iterative reconstruction (ADMIRE) represents a repetitive reconstruction method that can adjust strength and kernel, each of which are known to affect computed tomography (CT) image quality. The aim of this study was to quantitatively analyze the noise and spatial resolution of CT images according to ADMIRE control factors. Patient im- ages were obtained by applying ADMIRE strength 2 and 3, and kernel B40 and B59. For quantitative evaluations, the noise level, spatial resolution, and overall image quality were measured using coefficient of variation (COV), edge rise distance (ERD), and natural image quality evaluation (NIQE). The superior values for the average COV, ERD, and NIQE results were obtained for the ADMIRE reconstruction conditions of ADMIRE 2 + B40, ADMIRE 3 + B59, and ADMIRE3 + B59. NIQE, which represents the overall image quality based on no-reference, was about 6.04 when using ADMIRE 3 + B59, showing the best result among the reconstructed image acquisition conditions. The results of this study indicate that the ADMIRE strength and kernel chosen for use in ADMIRE reconstruction have a significant impact on CT image quality. This highlights the importance of adjusting to the control factors in consideration of the clinical environment. | - |
dc.format.extent | 8 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 대한방사선과학회 | - |
dc.title | Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters : A Pilot Study | - |
dc.type | Article | - |
dc.identifier.bibliographicCitation | 방사선기술과학, v.47, no.3, pp 175 - 182 | - |
dc.identifier.kciid | ART003093082 | - |
dc.description.isOpenAccess | N | - |
dc.citation.endPage | 182 | - |
dc.citation.startPage | 175 | - |
dc.citation.title | 방사선기술과학 | - |
dc.citation.volume | 47 | - |
dc.citation.number | 3 | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | Computed tomography | - |
dc.subject.keywordAuthor | Advanced modeled iterative reconstruction (ADMIRE) | - |
dc.subject.keywordAuthor | Iteration intensity and kernel | - |
dc.subject.keywordAuthor | Noise level and spatial resolution evaluations | - |
dc.subject.keywordAuthor | Blind image quality evaluation | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.