Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Practical Dose Parameter Values for the Prediction of the Adverse Effect of Neurointerventional Radiation: Relationship Between the Dose Parameters and Temporary Alopecia After Intracranial Coil Embolization

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Dae Han-
dc.contributor.authorYoo, Chan Jong-
dc.contributor.authorPark, Cheol Wan-
dc.contributor.authorKim, Myeong Jin-
dc.date.available2020-02-27T02:21:50Z-
dc.date.created2020-02-04-
dc.date.issued2019-10-
dc.identifier.issn1878-8750-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/955-
dc.description.abstractOBJECTIVE: To present values for the dose parameters predictive of alopecia as an adverse effect induced by neuroembolization using a biplane fluoroscopy. METHODS: This study included a total of 151 patients (52 men, mean age of 55.1 +/- 12.2 years) treated for intracranial neuroembolization between 2014 to 2018 with the following criteria: 1) obtainable dose report with digital subtraction angiographic image records, 2) no history of radiation exposure 6 months prior to the first procedure, and 3) and clinical follow-up performed through 12 months following the procedure. Patients were divided into 2 groups according to their presentation of alopecia during the follow-up period. RESULTS: Eighteen (11.9%) patients developed alopecia 10 to 30 days after the procedure (average: 18.5 +/- 5.3 days). Sixteen (88.9%) patients in the alopecia group were affected by projection of the A-plane fluoroscopy. Area under the receiver operating characteristic analysis curves of 0.865 (P = 0.000) and 0.831 (P = 0.000) were used to compute the optimal A-plane dose area product (255.4 Gy-cm(2); sensitivity: 0.875; specificity: 0.805; Youden J = 0.682) and cumulative dose (4437.5 mGy; sensitivity, 0.750; specificity, 0.805; Youden J = 0.556) cutoff values, respectively, capable of distinguishing patients with alopecia (n = 16) from subtotal patients (n = 149). CONCLUSIONS: The dose area product and the cumulative dose may be useful, intuitive factors for predicting the adverse effects of the neurointerventional radiation. Further multicenter research should be performed to confirm the efficacy and utility of the reference values of dose area product and cumulative dose for preventing excessive irradiation during neurointerventional procedures.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.relation.isPartOfWORLD NEUROSURGERY-
dc.titlePractical Dose Parameter Values for the Prediction of the Adverse Effect of Neurointerventional Radiation: Relationship Between the Dose Parameters and Temporary Alopecia After Intracranial Coil Embolization-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000488248200028-
dc.identifier.doi10.1016/j.wneu.2019.06.039-
dc.identifier.bibliographicCitationWORLD NEUROSURGERY, v.130, pp.E222 - E229-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85068736745-
dc.citation.endPageE229-
dc.citation.startPageE222-
dc.citation.titleWORLD NEUROSURGERY-
dc.citation.volume130-
dc.contributor.affiliatedAuthorChoi, Dae Han-
dc.contributor.affiliatedAuthorYoo, Chan Jong-
dc.contributor.affiliatedAuthorPark, Cheol Wan-
dc.contributor.affiliatedAuthorKim, Myeong Jin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorAlopecia-
dc.subject.keywordAuthorDose-
dc.subject.keywordAuthorEmbolization-
dc.subject.keywordAuthorFluoroscopy-
dc.subject.keywordAuthorRadiation-
dc.subject.keywordPlusAREA PRODUCT-
dc.subject.keywordPlusINTERVENTIONAL NEURORADIOLOGY-
dc.subject.keywordPlusAIR KERMA-
dc.subject.keywordPlusCEREBRAL-ANGIOGRAPHY-
dc.subject.keywordPlusSKIN-
dc.subject.keywordPlusPATIENT-
dc.subject.keywordPlusEXPOSURE-
dc.subject.keywordPlusFLUOROSCOPY-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryClinical Neurology-
dc.relation.journalWebOfScienceCategorySurgery-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Cheol Wan photo

Park, Cheol Wan
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE