Detailed Information

Cited 23 time in webofscience Cited 26 time in scopus
Metadata Downloads

Effects of interfacial layer wettability and thickness on the coating morphology and sirolimus release for drug-eluting stent

Full metadata record
DC Field Value Language
dc.contributor.authorBedair, Tarek M.-
dc.contributor.authorYu, Seung Jung-
dc.contributor.authorIm, Sung Gap-
dc.contributor.authorPark, Bang Ju-
dc.contributor.authorJoung, Yoon Ki-
dc.contributor.authorHan, Dong Keun-
dc.date.available2020-02-28T06:45:03Z-
dc.date.created2020-02-06-
dc.date.issued2015-12-15-
dc.identifier.issn0021-9797-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/9812-
dc.description.abstractDrug-eluting stents (DESs) have been used to treat coronary artery diseases by placing in the arteries. However, current DESs still suffer from polymer coating defects such as delamination and peeling-off that follows stent deployment. Such coating defects could increase the roughness of DES and might act as a source of late or very late thrombosis and might increase the incident of restenosis. In this regard, we modified the cobalt-chromium (Co-Cr) alloy surface with hydrophilic poly(2-hydroxyethyl methacrylate) (PHEMA) or hydrophobic poly(2-hydroxyethyl methacrylate)-grafted-poly(caprolactone) (PHEMA-g-PCL) brushes. The resulting surfaces were biocompatible and biodegradable, which could act as anchoring layer for the drug-in-polymer matrix coating. The two modifications were characterized by ATR-FTIR, XPS, water contact angle measurements, SEM and AFM. On the control and modified Co-Cr samples, a sirolimus (SRL)-containing poly(D,L-lactide) (PDLLA) were ultrasonically spray-coated, and the drug release was examined for 8 weeks under physiological conditions. The results demonstrated that PHEMA as a primer coating improved the coating stability and degradation morphology, and drug release profile for short-term as compared to control Co-Cr, but fails after 7 weeks in physiological buffer. On the other hand, the hydrophobic PHEMA-g-PCL brushes not only enhanced the stability and degradation morphology of the PDLLA coating layer, but also sustained SRL release for long-term. At 8-week of release test, the surface morphologies and release profiles of coated PDLLA layers verified the beneficial effect of hydrophobic PCL brushes as well as their thickness on coating stability. Our study concludes that 200 nm thickness of PHEMA-g-PCL as interfacial layer affects the stability and degradation morphology of the biodegradable coating intensively to be applied for various biodegradable-based DESs. (C) 2015 Elsevier Inc. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherACADEMIC PRESS INC ELSEVIER SCIENCE-
dc.relation.isPartOfJOURNAL OF COLLOID AND INTERFACE SCIENCE-
dc.subjectCHEMICAL-VAPOR-DEPOSITION-
dc.subjectIN-VITRO DEGRADATION-
dc.subjectPOLY(2-HYDROXYETHYL METHACRYLATE)-
dc.subjectSURFACE-
dc.subjectTITANIUM-
dc.subjectTHROMBOGENICITY-
dc.subjectIMPLANTATION-
dc.subjectDURABILITY-
dc.subjectMONOLAYERS-
dc.subjectSTABILITY-
dc.titleEffects of interfacial layer wettability and thickness on the coating morphology and sirolimus release for drug-eluting stent-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000363077800023-
dc.identifier.doi10.1016/j.jcis.2015.08.051-
dc.identifier.bibliographicCitationJOURNAL OF COLLOID AND INTERFACE SCIENCE, v.460, pp.189 - 199-
dc.identifier.scopusid2-s2.0-84940048168-
dc.citation.endPage199-
dc.citation.startPage189-
dc.citation.titleJOURNAL OF COLLOID AND INTERFACE SCIENCE-
dc.citation.volume460-
dc.contributor.affiliatedAuthorPark, Bang Ju-
dc.type.docTypeArticle-
dc.subject.keywordAuthorDrug-eluting stent-
dc.subject.keywordAuthorBiodegradable polymer-
dc.subject.keywordAuthorRing-opening polymerization-
dc.subject.keywordAuthorPhoto-initiated chemical vapor deposition-
dc.subject.keywordAuthorPolymer brush-
dc.subject.keywordPlusCHEMICAL-VAPOR-DEPOSITION-
dc.subject.keywordPlusIN-VITRO DEGRADATION-
dc.subject.keywordPlusPOLY(2-HYDROXYETHYL METHACRYLATE)-
dc.subject.keywordPlusSURFACE-
dc.subject.keywordPlusTITANIUM-
dc.subject.keywordPlusTHROMBOGENICITY-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusDURABILITY-
dc.subject.keywordPlusMONOLAYERS-
dc.subject.keywordPlusSTABILITY-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Physical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 전자공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Bang Ju photo

Park, Bang Ju
반도체대학 (반도체·전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE