Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of detailed pediatric eye models for lens dose calculations

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Haegin-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorNguyen, Thang Tat-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorShin, Bangho-
dc.contributor.authorMoon, Sungho-
dc.contributor.authorHa, Sangseok-
dc.contributor.authorSon, Gahee-
dc.contributor.authorAugusteyn, Robert-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2021-07-30T04:43:23Z-
dc.date.available2021-07-30T04:43:23Z-
dc.date.created2021-07-14-
dc.date.issued2021-06-
dc.identifier.issn0952-4746-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/1064-
dc.description.abstractThe International Commission on Radiological Protection (ICRP) recently reduced the dose limit for the eye lens for occupational exposure from 150 mSv yr(-1) to 20 mSv yr(-1), as averaged over defined periods of five years, with no annual dose in a single year exceeding 50 mSv, emphasizing the importance of the accurate estimation of lens dose. In the present study, for more accurate lens dosimetry, detailed eye models were developed for children and adolescents (newborns and 1, 5, 10, and 15 year olds), which were then incorporated into the pediatric mesh-type reference computational phantoms (MRCPs) and used to calculate lens dose coefficients (DCs) for photon and electron exposures. Finally, the calculated values were compared with those calculated with the adult MRCPs in order to determine the age dependence of the lens DCs. For photon exposures, the lens DCs of the pediatric MRCPs showed some sizable differences from those of the adult MRCPs at very low energies (10 and 15 keV), but the differences were all less than 35%, except for the posterior-anterior irradiation geometry, for which the lens dose is not of primary concern. For electron exposures, much larger differences were found. For the anterior-posterior (AP) and isotropic irradiation geometries, the largest differences between the lens DCs of the pediatric and adult phantoms were found in the energy range of 0.6-1 MeV, where the newborn lens DCs were larger by up to a factor of similar to 5 than the adult. The lens DCs of the present study, which were calculated for the radiosensitive region of the lens, also were compared with those for the entire lens in the AP irradiation geometry. Our results showed that the DCs of the entire lens were similar to those of the radiosensitive region for 0.02-2 MeV photons and >2 MeV electrons, but that for the other energy ranges, significant differences were noticeable, i.e. 10%-40% for photons and up to a factor of similar to 5 for electrons.-
dc.language영어-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.titleDevelopment of detailed pediatric eye models for lens dose calculations-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1088/1361-6498/abfa32-
dc.identifier.scopusid2-s2.0-85107711758-
dc.identifier.wosid000657108700001-
dc.identifier.bibliographicCitationJOURNAL OF RADIOLOGICAL PROTECTION, v.41, no.2, pp.305 - 325-
dc.relation.isPartOfJOURNAL OF RADIOLOGICAL PROTECTION-
dc.citation.titleJOURNAL OF RADIOLOGICAL PROTECTION-
dc.citation.volume41-
dc.citation.number2-
dc.citation.startPage305-
dc.citation.endPage325-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCONVERSION COEFFICIENTS-
dc.subject.keywordPlusULTRASONIC MEASUREMENT-
dc.subject.keywordPlusCRYSTALLINE LENS-
dc.subject.keywordPlusSAGITTAL GROWTH-
dc.subject.keywordPlusFETAL ORBIT-
dc.subject.keywordPlusCURVATURE-
dc.subject.keywordPlusEXPOSURE-
dc.subject.keywordPlusPHANTOMS-
dc.subject.keywordPlusBIRTH-
dc.subject.keywordPlusMESH-
dc.subject.keywordAuthordetailed eye model-
dc.subject.keywordAuthorpediatric lens dose coefficients-
dc.subject.keywordAuthorICRP reference phantom-
dc.subject.keywordAuthormesh-type phantom-
dc.subject.keywordAuthorMonte Carlo-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/1361-6498/abfa32-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE