Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Can Anodal Transcranial Direct Current Stimulation Increase Steady-State Visual Evoked Potential Responses?

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Do-Won-
dc.contributor.authorKim, Euijin-
dc.contributor.authorLee, Chany-
dc.contributor.authorIm, Chang Hwan-
dc.date.accessioned2021-08-02T10:51:24Z-
dc.date.available2021-08-02T10:51:24Z-
dc.date.created2021-05-12-
dc.date.issued2019-11-
dc.identifier.issn1011-8934-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/12353-
dc.description.abstractBackground: It has been frequently reported that non-negligible numbers of individuals have steady-state visual evoked potential (SSVEP) responses of low signal-to-noise-ratio (SNR) to specific stimulation frequencies, which makes detection of the SSVEP difficult especially in brain-computer interface applications. We investigated whether SSVEP can be modulated by anodal transcranial direct-current stimulation (tDCS) of the visual cortex. Methods: Each participant participated in two 20-min experiments-an actual tDCS experiment and a sham tDCS experiment-that were conducted on different days. Two representative electroencephalogram (EEG) features used for the SSVEP detection, SNR and amplitude, were tested for pre- and post-tDCS conditions to observe the effect of the anodal tDCS. Results: The EEG features were significantly enhanced by the anodal tDCS for the electrodes with low pre-tDCS SNR values, whereas the effect was not significant for electrodes with relatively higher SNR values. Conclusion: Anodal tDCS of the visual cortex may be effective in enhancing the SNR and amplitude of the SSVEP response especially for individuals with low-SNR SSVEP.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN ACAD MEDICAL SCIENCES-
dc.titleCan Anodal Transcranial Direct Current Stimulation Increase Steady-State Visual Evoked Potential Responses?-
dc.typeArticle-
dc.contributor.affiliatedAuthorIm, Chang Hwan-
dc.identifier.doi10.3346/jkms.2019.34.e285-
dc.identifier.scopusid2-s2.0-85074723399-
dc.identifier.wosid000496501500004-
dc.identifier.bibliographicCitationJOURNAL OF KOREAN MEDICAL SCIENCE, v.34, no.43, pp.1 - 12-
dc.relation.isPartOfJOURNAL OF KOREAN MEDICAL SCIENCE-
dc.citation.titleJOURNAL OF KOREAN MEDICAL SCIENCE-
dc.citation.volume34-
dc.citation.number43-
dc.citation.startPage1-
dc.citation.endPage12-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002521702-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusFREQUENCY RECOGNITION-
dc.subject.keywordPlusSSVEP-
dc.subject.keywordPlusCORTEX-
dc.subject.keywordPlusMODULATION-
dc.subject.keywordPlusTDCS-
dc.subject.keywordPlusBCI-
dc.subject.keywordAuthorTranscranial Direct Current Stimulation-
dc.subject.keywordAuthorElectroencephalography-
dc.subject.keywordAuthorSteady-State Visual Evoked Potential-
dc.subject.keywordAuthorPrimary Visual Cortex-
dc.identifier.urlhttps://jkms.org/DOIx.php?id=10.3346/jkms.2019.34.e285-
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Im, Chang Hwan photo

Im, Chang Hwan
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE