Cited 0 time in
중공사막 제습 기반 환기시스템의 여름철 에너지 절감 효과 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 조혜진 | - |
| dc.contributor.author | 천성용 | - |
| dc.contributor.author | 이재희 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2021-09-27T06:14:27Z | - |
| dc.date.available | 2021-09-27T06:14:27Z | - |
| dc.date.created | 2021-08-27 | - |
| dc.date.issued | 2021-06-25 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/132983 | - |
| dc.description.abstract | This study aimed to evaluate the energy saving potentials of a hollow fiber membrane dehumidification-based energy recovery ventilation system via a series of energy simulations. The proposed ventilation system is composed of an air-to-air hollow fiber membrane-based latent heat exchanger and flat plate sensible heat exchanger. According to the outdoor air conditions, the operation strategies of the proposed system could be classified into four type: total heat exchange mode, sensible heat exchange mode, latent heat exchange mode, and by-pass mode. For evaluating the energy and operating performance of the proposed system, the commercial energy recovery ventilator (ERV) system was chosen as a reference system. The simulation results present that the proposed system could provide the ventilation air at nearly neutral humidity ratio owing to the higher latent exchange effectiveness. In addition, the hollow fiber membrane latent heat exchanger in the proposed system could reduce 42% of the latent load in the introduced outdoor air. Therefore, the proposed system could conserve 26.5% of the primary energy consumption compared with the reference system. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | (사)대한설비공학회 | - |
| dc.title | 중공사막 제습 기반 환기시스템의 여름철 에너지 절감 효과 분석 | - |
| dc.title.alternative | Energy impacts of a hollow fiber membrane dehumidification-based ventilation system | - |
| dc.type | Conference | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 대한설비공학회 2021 하계학술발표대회, pp.611 - 614 | - |
| dc.relation.isPartOf | 대한설비공학회 2021 하계학술발표대회 | - |
| dc.relation.isPartOf | 대한설비공학회 2021 하계학술발표대회 논문집 | - |
| dc.citation.title | 대한설비공학회 2021 하계학술발표대회 | - |
| dc.citation.startPage | 611 | - |
| dc.citation.endPage | 614 | - |
| dc.citation.conferencePlace | KO | - |
| dc.citation.conferencePlace | 휘닉스 평창 | - |
| dc.citation.conferenceDate | 2021-06-22 | - |
| dc.type.rims | CONF | - |
| dc.description.journalClass | 2 | - |
| dc.identifier.url | https://www.auric.or.kr/User/Rdoc/DocRdoc.aspx?returnVal=RD_R&dn=407408#.YRxppN9t-Uk | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.