Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Intraocular pressure estimation method based on eye vibration responses

Full metadata record
DC Field Value Language
dc.contributor.authorKim, D.-
dc.contributor.authorChung, Y.-
dc.contributor.authorPark, Jun hong-
dc.contributor.authorJeon, Jin Yong-
dc.contributor.authorLee, Won June-
dc.date.accessioned2021-09-27T06:16:29Z-
dc.date.available2021-09-27T06:16:29Z-
dc.date.created2021-08-27-
dc.date.issued2020-08-23-
dc.identifier.issn0736-2935-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/133051-
dc.description.abstractIntraocular pressure (IOP) is a core vital sign and a proven risk factor for glaucoma development and progression. IOP measurement is important for the treatment and monitoring of glaucoma. In this study, we investigated a correlation between elevated IOP and ocular vibration responses. In order to find the correlation, a vibration response measurement experiment was conducted according to elevate in IOP. Four ex-vivo porcine eyes were used in the experiment. The IOP was elevated by injecting a solution into the eye. The experimental results derived the correlation between the IOP and the vibration response through frequency analysis and predicted the IOP based on the vibration response through the regression equation. Further, the deep learning model was presented by increasing the data and more accurate predictions were obtained compared to conventional regression formulas.-
dc.language영어-
dc.language.isoen-
dc.publisherKorean Society of Noise and Vibration Engineering-
dc.titleIntraocular pressure estimation method based on eye vibration responses-
dc.typeConference-
dc.contributor.affiliatedAuthorPark, Jun hong-
dc.contributor.affiliatedAuthorJeon, Jin Yong-
dc.contributor.affiliatedAuthorLee, Won June-
dc.identifier.scopusid2-s2.0-85101327160-
dc.identifier.bibliographicCitation49th International Congress and Exposition on Noise Control Engineering, INTER-NOISE 2020, pp.5800 - 5802-
dc.relation.isPartOf49th International Congress and Exposition on Noise Control Engineering, INTER-NOISE 2020-
dc.relation.isPartOfProceedings of 2020 International Congress on Noise Control Engineering, INTER-NOISE 2020-
dc.citation.title49th International Congress and Exposition on Noise Control Engineering, INTER-NOISE 2020-
dc.citation.startPage5800-
dc.citation.endPage5802-
dc.citation.conferencePlaceKO-
dc.citation.conferencePlaceCOEX Convention Center-
dc.citation.conferenceDate2020-08-23-
dc.type.rimsCONF-
dc.description.journalClass1-
dc.identifier.urlhttps://www.ingentaconnect.com/contentone/ince/incecp/2020/00000261/00000001/art00091-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 2. Conference Papers
서울 공과대학 > 서울 건축공학부 > 2. Conference Papers
서울 공과대학 > 서울 기계공학부 > 2. Conference Papers

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won June photo

Lee, Won June
COLLEGE OF MEDICINE (DEPARTMENT OF OPHTHALMOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE