Detailed Information

Cited 8 time in webofscience Cited 9 time in scopus
Metadata Downloads

Dose coefficients of mesh-type ICRP reference computational phantoms for idealized external exposures of photons and electrons

Full metadata record
DC Field Value Language
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorHan, Haegin-
dc.contributor.authorLee, Hanjin-
dc.contributor.authorShin, Bangho-
dc.contributor.authorThang Tat Nguyen-
dc.contributor.authorHan, Min Cheol-
dc.contributor.authorLee, Choonsik-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2021-08-02T11:29:59Z-
dc.date.available2021-08-02T11:29:59Z-
dc.date.created2021-05-12-
dc.date.issued2019-06-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/13442-
dc.description.abstractIn the present study, we established a comprehensive dataset of dose coefficients (DCs) of the new mesh-type ICRP reference computational phantoms (MRCPs) for idealized external exposures of photons and electrons with the Geant4 code. Subsequently, the DCs for the nine organs/tissues, calculated for their thin radiosensitive target regions, were compared with the values calculated by averaging the absorbed doses over the entire organ/tissue regions to observe the influence of the thin sensitive regions on dose calculations. The result showed that the influences for both photons and electrons were generally insignificant for the majority of organs/tissues, but very large for the skin and eye lens, especially for electrons. Furthermore, the large influence for the skin eventually affected the effective dose calculations for electrons. The DCs of the MRCPs also were compared with the current ICRP-116 values produced with the current ICRP-110 reference phantoms. The result showed that the DCs for the majority of organs/tissues and effective dose were generally similar to the ICRP-116 values for photons, except for very low energies; however, for electrons, significant differences from the ICRP-116 values were found in the DCs, particularly for superficial organs/tissues and skeletal tissues, and also for effective dose.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN NUCLEAR SOC-
dc.titleDose coefficients of mesh-type ICRP reference computational phantoms for idealized external exposures of photons and electrons-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1016/j.net.2018.12.006-
dc.identifier.scopusid2-s2.0-85064082177-
dc.identifier.wosid000462778100025-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, v.51, no.3, pp.843 - 852-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.titleNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.volume51-
dc.citation.number3-
dc.citation.startPage843-
dc.citation.endPage852-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002455865-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusCONVERSION COEFFICIENTS-
dc.subject.keywordAuthorDose coefficients-
dc.subject.keywordAuthorICRP-
dc.subject.keywordAuthorReference phantoms-
dc.subject.keywordAuthorMesh-
dc.subject.keywordAuthorMonte Carlo-
dc.subject.keywordAuthorGeant4-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573318306910?via%3Dihub-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE