Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Jong Deok | - |
dc.contributor.author | Lee, Won Hyuk | - |
dc.contributor.author | Lee, Yonggu | - |
dc.contributor.author | Lee, Hyun Ju | - |
dc.contributor.author | Cha, Teahyen | - |
dc.contributor.author | Kim, Seung Hyun | - |
dc.contributor.author | Song, Ki-Min | - |
dc.contributor.author | Lim, Young-Hyo | - |
dc.contributor.author | Cho, Seok Hyun | - |
dc.contributor.author | Cho, Sung Ho | - |
dc.contributor.author | Park, Hyun-Kyung | - |
dc.date.accessioned | 2021-08-02T11:30:12Z | - |
dc.date.available | 2021-08-02T11:30:12Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2019-06 | - |
dc.identifier.issn | 2054-5703 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/13462 | - |
dc.description.abstract | Vital sign monitoring in neonates requires adhesive electrodes, which often damage fragile newborn skin. Because impulse radio ultrawideband (IR-UWB) radar has been reported to recognize chest movement without contact in adult humans, IR-UWB may be used to measure respiratory rates (RRs) in a non-contact fashion. We investigated the feasibility of radar sensors for respiration monitoring in neonates without any respiratory support to compare the accuracy and reliability of radar measurements with those of conventional impedance pneumography measurements. In the neonatal intensive care unit, RRs were measured using radar (RRRd) and impedance pneumography (RRIP) simultaneously. The neonatal voluntary movements were measured using the radar sensor and categorized into three levels (low [M₀], intermediate [M₁] and high [M₂]). RRRd highly agreed with RRIP (r = 0.90; intraclass correlation coefficient [ICC] = 0.846 [0.835-0.856]). For the M-0 movement, there was good agreement between RRRd and RRIP (ICC = 0.893; mean bias -0.15 [limits of agreement (LOA) -9.6 to 10.0]). However, the agreement was slightly lower for the M-1 (ICC = 0.833; mean bias = 0.95 [LOA -11.4 to 13.3]) and M-2 (ICC = 0.749; mean bias = 3.04 [LOA -9.30 to 15.4]) movements than for the M-0 movement. In conclusion, IR-UWB radar cart provide accurate and reliable estimates of RR in neonates in a non-contact fashion. The performance of radar measurements could be affected by neonate movement. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | ROYAL SOC | - |
dc.title | Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Yonggu | - |
dc.contributor.affiliatedAuthor | Lee, Hyun Ju | - |
dc.contributor.affiliatedAuthor | Lim, Young-Hyo | - |
dc.contributor.affiliatedAuthor | Park, Hyun-Kyung | - |
dc.identifier.doi | 10.1098/rsos.190149 | - |
dc.identifier.scopusid | 2-s2.0-85068226560 | - |
dc.identifier.wosid | 000473797400022 | - |
dc.identifier.bibliographicCitation | ROYAL SOCIETY OPEN SCIENCE, v.6, no.6 | - |
dc.relation.isPartOf | ROYAL SOCIETY OPEN SCIENCE | - |
dc.citation.title | ROYAL SOCIETY OPEN SCIENCE | - |
dc.citation.volume | 6 | - |
dc.citation.number | 6 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.subject.keywordPlus | UWB | - |
dc.subject.keywordPlus | INFANTS | - |
dc.subject.keywordAuthor | non-contact sensor | - |
dc.subject.keywordAuthor | impulse radio ultrawideband radar | - |
dc.subject.keywordAuthor | newborn | - |
dc.subject.keywordAuthor | respiratory rate | - |
dc.subject.keywordAuthor | neonatal intensive care unit | - |
dc.identifier.url | https://royalsocietypublishing.org/doi/10.1098/rsos.190149 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.