Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

CMUTS in permanent contact operation for high output pressure

Full metadata record
DC Field Value Language
dc.contributor.authorHo, Min-Chieh-
dc.contributor.authorHoffmann, Maik Hoffmann-
dc.contributor.authorUnger, Alexander-
dc.contributor.authorPark, Kwan Kyu-
dc.contributor.authorKupnik, Mario-
dc.contributor.authorKhuri-Yakub, Butrus T.-
dc.date.accessioned2022-07-04T07:57:06Z-
dc.date.available2022-07-04T07:57:06Z-
dc.date.created2022-05-26-
dc.date.issued2015-11-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/138303-
dc.description.abstractWe present the operation of capacitive micromachined ultrasonic transducers (CMUTs) in permanent contact mode as an efficient transducer. The gap height of our transducers is chosen to be slightly smaller than the static deflection of the plate due to the pressure difference between the ambient and the vacuum cavity. Thus, the plates are in contact with the bottom of the cavities even with no dc bias applied. The devices were fabricated based on the thick box process. High-temperature assisted direct wafer bonding technique was used to fabricate devices with such large cell size (radii ~ 2000 μm) featuring low frequencies ~100 - 150 kHz. Extensive acoustic characterization was performed to demonstrate the behavior of such CMUTs in terms of displacement profile, output pressure and acoustic pitch-catch response. A maximum sound pressure of ~145 dB (SPL) at the transducer surface is measured at 240 V dc and 10V ac with 100 cycles of burst signal. This is a great improvement from conventional CMUTs (with deeper gap height, operating at 55 kHz), which requires 350 V dc and 200 V ac in order to achieve an output pressure of 129 dB (SPL) at the transducer surface. The results presented in this paper demonstrate that operating CMUTs in permanent contact mode indeed enhances the device output pressure, and provides a good candidate for efficient ultrasonic transducers.-
dc.language영어-
dc.language.isoen-
dc.publisherAmerican Society of Mechanical Engineers-
dc.titleCMUTS in permanent contact operation for high output pressure-
dc.typeConference-
dc.contributor.affiliatedAuthorPark, Kwan Kyu-
dc.identifier.scopusid2-s2.0-84953931727-
dc.identifier.bibliographicCitationASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems, InterPACK 2015, collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels-
dc.relation.isPartOfASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems, InterPACK 2015, collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels-
dc.relation.isPartOfASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems, InterPACK 2015, collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels-
dc.citation.titleASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems, InterPACK 2015, collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels-
dc.citation.conferencePlaceUS-
dc.citation.conferenceDate2015-07-06-
dc.type.rimsCONF-
dc.description.journalClass1-
dc.identifier.urlhttps://asmedigitalcollection.asme.org/InterPACK/proceedings-abstract/InterPACK2015/56901/V003T07A012/262790-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 2. Conference Papers

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Kwan Kyu photo

Park, Kwan Kyu
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE