| dc.description.abstract | Currently, the diagnosis of chronic kidney disease (CKD) is generally made by painful and prolonged procedures for blood screening. Therefore, it is desirable to develop rapid, non-invasive monitoring strategies as an alternative. It is noted that the majority of the typical molecular markers related to the progression and diagnosis of CKD have not been explored sufficiently for the clinical applications. This review extends systematic and critical overview on the microfluidic wearable biosensors for the monitoring of CKD associated targets in peripheral body fluids (e.g., interstitial fluid (ISF), sweat, saliva, and tears). The performance of recently reported wearable devices is also assessed in terms of various quality assurance parameters used for the analysis of CKD related metabolites (i.e., limit of detection, measurement range, and analytical method). At last, our discussion is extended to the various challenges and future prospects for their practical adoption and upscaling. | - |
| dc.format.extent | 19 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Recent advances in wearable biosensors for non-invasive monitoring of specific metabolites and electrolytes associated with chronic kidney disease: Performance evaluation and future challenges | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.trac.2022.116570 | - |
| dc.identifier.scopusid | 2-s2.0-85125461336 | - |
| dc.identifier.wosid | 000793224800004 | - |
| dc.identifier.bibliographicCitation | TrAC - Trends in Analytical Chemistry, v.150, pp 1 - 19 | - |
| dc.citation.title | TrAC - Trends in Analytical Chemistry | - |
| dc.citation.volume | 150 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 19 | - |
| dc.type.docType | Review | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordPlus | INTERSTITIAL FLUID | - |
| dc.subject.keywordPlus | RENAL-FUNCTION | - |
| dc.subject.keywordPlus | URIC-ACID | - |
| dc.subject.keywordPlus | CREATININE LEVELS | - |
| dc.subject.keywordPlus | GLUCOSE SENSOR | - |
| dc.subject.keywordPlus | TEST STRIP | - |
| dc.subject.keywordPlus | UREA | - |
| dc.subject.keywordPlus | BIOMARKERS | - |
| dc.subject.keywordPlus | LACTATE | - |
| dc.subject.keywordPlus | ARRAY | - |
| dc.subject.keywordAuthor | Biosensor applications | - |
| dc.subject.keywordAuthor | Chronic kidney disease | - |
| dc.subject.keywordAuthor | Disease diagnosis | - |
| dc.subject.keywordAuthor | Non-invasive sensing | - |
| dc.subject.keywordAuthor | Point-of-care | - |
| dc.subject.keywordAuthor | Wearable sensing device | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S016599362200053X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.