Cited 0 time in
Development of data acquisition system for Belle II electromagnetic calorimeter
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Aulchenko, V. | - |
| dc.contributor.author | Bobrov, A. | - |
| dc.contributor.author | Cheon, Byung Gu | - |
| dc.contributor.author | Kuzmin, A. | - |
| dc.contributor.author | Longo, S. | - |
| dc.contributor.author | Matvienko, D. | - |
| dc.contributor.author | Miyabayashi, K. | - |
| dc.contributor.author | Nakamura, I. | - |
| dc.contributor.author | Nakao, M. | - |
| dc.contributor.author | Remnev, M. | - |
| dc.contributor.author | Roney, J.M. | - |
| dc.contributor.author | Shebalin, V. | - |
| dc.contributor.author | Shwartz, B. | - |
| dc.contributor.author | Unno, Y. | - |
| dc.contributor.author | Usov, Y.V. | - |
| dc.contributor.author | Vinokurova, A. | - |
| dc.contributor.author | Yamada, S. | - |
| dc.contributor.author | Zhulanov, V. | - |
| dc.date.accessioned | 2022-07-06T04:05:29Z | - |
| dc.date.available | 2022-07-06T04:05:29Z | - |
| dc.date.issued | 2022-05 | - |
| dc.identifier.issn | 0168-9002 | - |
| dc.identifier.issn | 1872-9576 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/138689 | - |
| dc.description.abstract | The electromagnetic calorimeter (ECL) is one of the primary subsystems of the Belle II detector, used to measure the direction and momentum of photons in a wide energy range. The ECL and its data acquisition system include 8736 CsI(Tl) counters and 628 highly configurable modules for data readout. Several features both in the firmware and in the software were implemented to ensure efficient operation during data taking. This paper describes the development of ECL firmware, corresponding configuration, initialization and monitoring software, along with the development of ECL run control. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Development of data acquisition system for Belle II electromagnetic calorimeter | - |
| dc.type | Article | - |
| dc.publisher.location | 네덜란드 | - |
| dc.identifier.doi | 10.1016/j.nima.2022.166468 | - |
| dc.identifier.scopusid | 2-s2.0-85125778949 | - |
| dc.identifier.wosid | 000784246700004 | - |
| dc.identifier.bibliographicCitation | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v.1030, pp 1 - 11 | - |
| dc.citation.title | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | - |
| dc.citation.volume | 1030 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 11 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Physics, Nuclear | - |
| dc.relation.journalWebOfScienceCategory | Physics, Particles & Fields | - |
| dc.subject.keywordPlus | Calorimeters | - |
| dc.subject.keywordPlus | Cesium iodide | - |
| dc.subject.keywordPlus | Data acquisition | - |
| dc.subject.keywordPlus | Readout systems | - |
| dc.subject.keywordPlus | Firmware | - |
| dc.subject.keywordPlus | Belle II | - |
| dc.subject.keywordPlus | DAQ | - |
| dc.subject.keywordPlus | Data acquisition system | - |
| dc.subject.keywordPlus | Data readout | - |
| dc.subject.keywordPlus | Electromagnetic calorimeter | - |
| dc.subject.keywordPlus | ITS data | - |
| dc.subject.keywordPlus | Slow control | - |
| dc.subject.keywordPlus | Wide energy range | - |
| dc.subject.keywordAuthor | Belle II | - |
| dc.subject.keywordAuthor | Electromagnetic calorimeter | - |
| dc.subject.keywordAuthor | DAQ | - |
| dc.subject.keywordAuthor | Slow control | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0168900222001036?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.