Cited 0 time in
Prognostic Impact of In-Hospital Use of Mechanical Cardiopulmonary Resuscitation Devices Compared with Manual Cardiopulmonary Resuscitation: A Nationwide Population-Based Observational Study in South Korea
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Wonhee | - |
| dc.contributor.author | Ahn, Chiwon | - |
| dc.contributor.author | Kim, In-Young | - |
| dc.contributor.author | Choi, Hyun-Young | - |
| dc.contributor.author | Kim, Jae-Guk | - |
| dc.contributor.author | Kim, Jihoon | - |
| dc.contributor.author | Shin, Hyungoo | - |
| dc.contributor.author | Moon, Shinje | - |
| dc.contributor.author | Lee, Juncheol | - |
| dc.contributor.author | Lee, Jongshill | - |
| dc.contributor.author | Cho, Youngsuk | - |
| dc.contributor.author | Lee, Yoonje | - |
| dc.contributor.author | Shin, Dong-Geum | - |
| dc.date.accessioned | 2022-07-06T08:37:52Z | - |
| dc.date.available | 2022-07-06T08:37:52Z | - |
| dc.date.issued | 2022-03 | - |
| dc.identifier.issn | 1010-660X | - |
| dc.identifier.issn | 1648-9144 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139296 | - |
| dc.description.abstract | Background and Objectives: This study analyzed the prognostic impact of mechanical cardiopulmonary resuscitation (CPR) devices in out-of-hospital cardiac arrest (OHCA) patients, in comparison to manual CPR. Materials and Methods: This study was a nationwide population-based observational study in South Korea. Data were retrospectively collected from 142,905 OHCA patients using the South Korean Out-of-Hospital Cardiac Arrest Surveillance database. We included adult OHCA patients who received manual or mechanical CPR in the emergency room. The primary outcome was survival at discharge and the secondary outcome was sustained return of spontaneous circulation (ROSC). Statistical analysis included propensity score matching and multivariate logistic regression. Results: A total of 19,045 manual CPR and 1125 mechanical CPR cases (671 AutoPulse™ vs. 305 Thumper™ vs. 149 LUCAS™) were included. In the matched multivariate analyses, all mechanical CPR devices were associated with a lower ROSC than that of manual CPR. AutoPulse™ was associated with lower survival in the multivariate analysis after matching (aOR with 95% CI: 0.57 (0.33–0.96)), but the other mechanical CPR devices were associated with similar survival to discharge as that of manual CPR. Witnessed arrest was commonly associated with high ROSC, but the use of mechanical CPR devices and cardiac origin arrest were associated with low ROSC. Only target temperature management was the common predictor for high survival. Conclusions: The mechanical CPR devices largely led to similar survival to discharge as that of manual CPR in OHCA patients; however, the in-hospital use of the AutoPulse™ device for mechanical CPR may significantly lower survival compared to manual CPR. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI | - |
| dc.title | Prognostic Impact of In-Hospital Use of Mechanical Cardiopulmonary Resuscitation Devices Compared with Manual Cardiopulmonary Resuscitation: A Nationwide Population-Based Observational Study in South Korea | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/medicina58030353 | - |
| dc.identifier.scopusid | 2-s2.0-85126009480 | - |
| dc.identifier.wosid | 000774070800001 | - |
| dc.identifier.bibliographicCitation | Medicina (Kaunas, Lithuania), v.58, no.3, pp 1 - 11 | - |
| dc.citation.title | Medicina (Kaunas, Lithuania) | - |
| dc.citation.volume | 58 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 11 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | General & Internal Medicine | - |
| dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
| dc.subject.keywordPlus | CHEST COMPRESSION DEVICE | - |
| dc.subject.keywordPlus | CARDIAC-ARREST PATIENTS | - |
| dc.subject.keywordPlus | LUCAS(TM) DEVICE | - |
| dc.subject.keywordPlus | BLOOD-FLOW | - |
| dc.subject.keywordPlus | CPR | - |
| dc.subject.keywordPlus | GUIDELINES | - |
| dc.subject.keywordAuthor | cardiopulmonary resuscitation | - |
| dc.subject.keywordAuthor | heart arrest | - |
| dc.subject.keywordAuthor | chest compression | - |
| dc.subject.keywordAuthor | mechanical device | - |
| dc.identifier.url | https://www.mdpi.com/1648-9144/58/3/353 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
