Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Han, Min Cheol | - |
| dc.contributor.author | Kim, Jihun | - |
| dc.contributor.author | Hong, Chae-Seon | - |
| dc.contributor.author | Chang, Kyung Hwan | - |
| dc.contributor.author | Han, Su Chul | - |
| dc.contributor.author | Park, Kwangwoo | - |
| dc.contributor.author | Kim, Dong Wook | - |
| dc.contributor.author | Kim, Hojin | - |
| dc.contributor.author | Chang, Jee Suk | - |
| dc.contributor.author | Kim, Jina | - |
| dc.contributor.author | Kye, Sunsuk | - |
| dc.contributor.author | Park, Ryeong Hwang | - |
| dc.contributor.author | Chung, Yoonsun | - |
| dc.contributor.author | Kim, Jin Sung | - |
| dc.date.accessioned | 2022-07-06T10:14:16Z | - |
| dc.date.available | 2022-07-06T10:14:16Z | - |
| dc.date.issued | 2022-02 | - |
| dc.identifier.issn | 1533-0346 | - |
| dc.identifier.issn | 1533-0338 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139487 | - |
| dc.description.abstract | Purpose: Various deformable image registration (DIR) methods have been used to evaluate organ deformations in 4-dimensional computed tomography (4D CT) images scanned during the respiratory motions of a patient. This study assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients with fiducial markers (FMs) implanted during the postoperative radiosurgery of multiple lung metastases. Methods: To evaluate DIR algorithms, 4D CT images of 5 patients were used, and ground-truths of FMs and tumors were generated by physicians based on their medical expertise. The positions of FMs and tumors in each 4D CT phase image were determined using 10 DIR algorithms, and the deformed results were compared with ground-truth data. Results: The target registration errors (TREs) between the FM positions estimated by optical flow algorithms and the ground-truth ranged from 1.82 +/- 1.05 to 1.98 +/- 1.17 mm, which is within the uncertainty of the ground-truth position. Two algorithm groups, namely, optical flow and demons, were used to estimate tumor positions with TREs ranging from 1.29 +/- 1.21 to 1.78 +/- 1.75 mm. With respect to the deformed position for tumors, for the 2 DIR algorithm groups, the maximum differences of the deformed positions for gross tumor volume tracking were approximately 4.55 to 7.55 times higher than the mean differences. Errors caused by the aforementioned difference in the Hounsfield unit values were also observed. Conclusions: We quantitatively evaluated 10 DIR algorithms using 4D CT images of 5 patients and compared the results with ground-truth data. The optical flow algorithms showed reasonable FM-tracking results in patient 4D CT images. The iterative optical flow method delivered the best performance in this study. With respect to the tumor volume, the optical flow and demons algorithms delivered the best performance. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Adenine Press | - |
| dc.title | Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1177/15330338221078464 | - |
| dc.identifier.scopusid | 2-s2.0-85124680309 | - |
| dc.identifier.wosid | 000759442500001 | - |
| dc.identifier.bibliographicCitation | Technology in Cancer Research and Treatment, v.21, pp 1 - 11 | - |
| dc.citation.title | Technology in Cancer Research and Treatment | - |
| dc.citation.volume | 21 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 11 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Oncology | - |
| dc.relation.journalWebOfScienceCategory | Oncology | - |
| dc.subject.keywordPlus | MODULATED RADIATION-THERAPY | - |
| dc.subject.keywordPlus | RESPIRATORY MOTION | - |
| dc.subject.keywordPlus | VALIDATION | - |
| dc.subject.keywordPlus | ERRORS | - |
| dc.subject.keywordPlus | FRAMEWORK | - |
| dc.subject.keywordPlus | POINT | - |
| dc.subject.keywordPlus | HEAD | - |
| dc.subject.keywordAuthor | deformable image registration | - |
| dc.subject.keywordAuthor | lung deformation | - |
| dc.subject.keywordAuthor | tumor tracking | - |
| dc.subject.keywordAuthor | fiducial marker tracking | - |
| dc.subject.keywordAuthor | multiple lung metastases | - |
| dc.identifier.url | https://journals.sagepub.com/doi/10.1177/15330338221078464 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.