Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Neckband-Based Continuous Blood Pressure Monitoring Device with Offset-Tolerant ROIC

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Kwangmuk-
dc.contributor.authorKang, YUMIN-
dc.contributor.authorPark, CHAN SAM-
dc.contributor.authorKim, HYUNJOONG-
dc.contributor.authorKeum, DAE SIK-
dc.contributor.authorJang, DONG PYO-
dc.contributor.authorKim, JAE JOON-
dc.date.accessioned2022-07-06T10:19:10Z-
dc.date.available2022-07-06T10:19:10Z-
dc.date.created2022-03-07-
dc.date.issued2022-02-
dc.identifier.issn2169-3536-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139581-
dc.description.abstractThis study presents a wearable neckband device for continuous cuffless blood pressure (BP) monitoring, where reliable neck-based BP measurement is achieved by utilizing the electrocardiogram (ECG) and impedance plethysmogram (IPG). Optimal composition and position of sensing electrodes around the neck were decided with consideration for physiological characteristics of the human body, and the core parameter of IPG magnitude was experimentally selected to improve the BP estimation accuracy. For its small-featured noises-tolerant detection capability, a customized readout integrated circuit (ROIC) was developed, which includes two kinds of analog front-ends (AFEs) for biopotential and bio-impedance. Both AFEs are proposed to include an attenuator-assisted hybrid DC-servo loop (DSL) structure, achieving precise pulse transit time (PTT) calculation by lowering the high-pass filtering cutoff frequency and also stable signal acquisition by widening the offset-cancellation range. Real-time PTT monitoring and BP estimation are wirelessly conducted, and its continuous operation time with 350-mAh battery capacity is longer than 5 hours. Efficacy of the proposed neckband BP device was evaluated for 8 healthy subjects under the physical stress condition, where the mean correlation coefficient and the standard deviation were achieved as 0.8508 and 4.17mmHg respectively.-
dc.language영어-
dc.language.isoen-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleNeckband-Based Continuous Blood Pressure Monitoring Device with Offset-Tolerant ROIC-
dc.typeArticle-
dc.contributor.affiliatedAuthorJang, DONG PYO-
dc.identifier.doi10.1109/ACCESS.2022.3149925-
dc.identifier.scopusid2-s2.0-85124739354-
dc.identifier.wosid000756531300001-
dc.identifier.bibliographicCitationIEEE Access, v.10, pp.17300 - 17309-
dc.relation.isPartOfIEEE Access-
dc.citation.titleIEEE Access-
dc.citation.volume10-
dc.citation.startPage17300-
dc.citation.endPage17309-
dc.type.rimsART-
dc.type.docTypeArticle in Press-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTelecommunications-
dc.relation.journalWebOfScienceCategoryComputer Science, Information Systems-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryTelecommunications-
dc.subject.keywordPlusAMPLIFIER-
dc.subject.keywordPlusCMOS-
dc.subject.keywordAuthorBiomedical monitoring-
dc.subject.keywordAuthorcontinuous blood pressure monitoring-
dc.subject.keywordAuthorElectrocardiography-
dc.subject.keywordAuthorElectrodes-
dc.subject.keywordAuthorEstimation-
dc.subject.keywordAuthorimpedance plethysmogram-
dc.subject.keywordAuthorMonitoring-
dc.subject.keywordAuthorNeck-
dc.subject.keywordAuthorNeckband device-
dc.subject.keywordAuthorpulse transit time-
dc.subject.keywordAuthorreadout integrated circuit-
dc.subject.keywordAuthorSensors-
dc.identifier.urlhttps://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9706480-
Files in This Item
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE