A study on Raman spectroscopic scheme enabling fast and accurate determination of calcite concentration in gypsum
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Seol, D | - |
| dc.contributor.author | Ma, Y | - |
| dc.contributor.author | Nam, K | - |
| dc.contributor.author | Chung, H | - |
| dc.date.accessioned | 2022-07-06T10:46:35Z | - |
| dc.date.available | 2022-07-06T10:46:35Z | - |
| dc.date.issued | 2022-01 | - |
| dc.identifier.issn | 0026-265X | - |
| dc.identifier.issn | 1095-9149 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139904 | - |
| dc.description.abstract | This study intended to develop a potential Raman spectroscopic measurement scheme able to simply and accurately determine the calcite concentration (impurity) in gypsum. The sample coverage area for measurements was a major concern since it directly influenced on the representation of sample composition. Initially, 16 synthetic gypsum samples containing varying calcite contents (0.01 ∼ 5.1 wt%) were prepared. For Raman spectral collection, both small spot illumination (50 μm in diameter) and wide area illumination (WAI, 6 mm in diameter) schemes were employed. When the microscope-based (small spot) scheme was used for the analysis, the accuracy of calcite concentration determination was not satisfactory since the sample coverage area was too small to average out the local compositional heterogeneity. The accuracy substantially improved by using the WAI-Raman measurement due to better representation of calcite concentrations in the samples. Next, when real process gypsum samples containing other minor impurities such as carbon residues were analyzed, the fluorescence background appeared due to the colored impurities. Nonetheless, the calcite peak clearly presented on top of the fluorescence background and thereby determination of calcite concentration was feasible. Again, the accuracy of WAI-Raman measurement was superior to the small-spot measurement. In overall, the more correct representation of calcite concentrations in gypsum samples by the WAI scheme was responsible for the improved accuracy. © 2021 Elsevier B.V. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | A study on Raman spectroscopic scheme enabling fast and accurate determination of calcite concentration in gypsum | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.microc.2021.106913 | - |
| dc.identifier.scopusid | 2-s2.0-85117599668 | - |
| dc.identifier.wosid | 000712594600002 | - |
| dc.identifier.bibliographicCitation | Microchemical Journal, v.172, pp 1 - 5 | - |
| dc.citation.title | Microchemical Journal | - |
| dc.citation.volume | 172 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 5 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordAuthor | Calcite impurity | - |
| dc.subject.keywordAuthor | Gypsum | - |
| dc.subject.keywordAuthor | Non-destructive analysis | - |
| dc.subject.keywordAuthor | Raman spectroscopy | - |
| dc.subject.keywordAuthor | Thermogravimetric analysis | - |
| dc.subject.keywordAuthor | Wide area illumination | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.