Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Self-sensing capacity of ultra-high-performance fiber-reinforced concrete containing conductive powders in tension

Authors
Lee, Seung-JungYou, IlhwanKim, SoonhoShin, Hyun-OhYoo, Doo-Yeol
Issue Date
Jan-2022
Publisher
Elsevier Ltd
Keywords
Cement-based sensor; Conductive powders; Self-sensing; Tensile response; Ultra-high-performance fiber-reinforced concrete
Citation
Cement and Concrete Composites, v.125, pp.1 - 15
Indexed
SCOPUS
Journal Title
Cement and Concrete Composites
Volume
125
Start Page
1
End Page
15
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/139917
DOI
10.1016/j.cemconcomp.2021.104331
ISSN
0958-9465
Abstract
This study experimentally analyzed the self-sensing performance of the tensile behavior of ultra-high-performance fiber-reinforced concrete (UHPFRC) incorporating four different types of conductive powders: carbon black (CB), nickel powder (NP), graphite powder (GP), and steel slag powder (SP). The conductive powders were incorporated by weight ratios of 5% and 10% of quartz powder (QP) which is used as a mechanical filler of UHPFRC. The results showed a decrease in tensile strength with an increase in the incorporated amount of CB, NP, and GP and an increase in tensile strength according to the increase in the incorporated amount of SP from 5% to 10%. The results of microstructure analysis by EDS mapping showed that, when incorporating 5% of CB and GP, which have a lower density than QP, conductive powders were sufficiently distributed, enabling both direct contact between conductive powders and the tunneling effect. In the case of NP and SP, which have a higher density than QP, at least 10% of NP and SP must be incorporated to achieve self-sensing performance. The tensile stress/strain versus time responses of UHPFRC with conductive powders were simulated using the measured FCRs. The pre-peak tensile behaviors were also well simulated using empirical equations based on the obtained FCR by nonlinear regression analysis. The predicted pre-peak tensile behaviors had smaller errors compared to the experimentally obtained tensile behaviors. In the case of the post-peak, only tensile stress was well simulated. As a result, 10% of NP and 5% of GP had sufficient self-sensing performance for UHPFRC with conductive powders.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Doo Yeol photo

Yoo, Doo Yeol
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE