Variable-focus optoacoustic lens with wide dynamic range and long focal length by using a flexible polymer nano-composite membrane
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abbasi, Muhammad Awais | - |
dc.contributor.author | Faraz, Muhammad | - |
dc.contributor.author | Joo, Min Gyu | - |
dc.contributor.author | Son, Donghee | - |
dc.contributor.author | Won, Sang Min | - |
dc.contributor.author | Ok, Jong G. | - |
dc.contributor.author | Park, Hui Joon | - |
dc.contributor.author | Baac, Hyoung Won | - |
dc.date.accessioned | 2022-07-06T11:10:02Z | - |
dc.date.available | 2022-07-06T11:10:02Z | - |
dc.date.created | 2021-11-22 | - |
dc.date.issued | 2021-12 | - |
dc.identifier.issn | 0041-624X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/140241 | - |
dc.description.abstract | We demonstrate a variable-focus optoacoustic lens (VFOL) by pneumatically controlling a flexible polymer nano-composite membrane, which can produce laser-generated focused ultrasound (LGFU) with a high peak amplitude (>30 MPa) and a tight focal dimension (several hundred μm) over a wide dynamic range of focus variation (>20 mm) together with a long focal length up to 60 mm, each of which is widest and longest among optoacoustic lenses developed so far. Two different designs in lens dimension have been fabricated and characterized: VFOL-L with a 40-mm diameter and VFOL-S with 10 mm. VFOL-L exhibits a wide dynamic range of focal length variation from 38.52 to 60.39 mm with a center frequency near ~ 10 MHz, which is proper for practical long-range applications with several-cm depth. In comparison, VFOL-S covers a focal variation range from 6.75 to 11.1 mm with ~ 14 MHz, producing a relatively higher-pressure amplitude, which allows the inception of acoustic cavitation at an impedance-mismatched boundary. The nano-composite membrane of VFOL is actuated from a planar to deeply curved shape by externally injecting liquid into the VFOL, resulting in a focal gain up to 255 and a positive peak pressure of > 30 MPa in the VFOL-L case. The minimum-geometrical f-number as low as 0.963 is achieved at the shortest focal length (38.52 mm) with 6-dB lateral and axial spot dimensions of 304 μm and 2.86 mm, respectively. We expect that the proposed VFOL-based LGFU with a high peak pressure, a wide dynamic axial range, and a tight focal dimension are suitably applied for depth-dependent characterization of tissues and shockwave treatment, taking advantages of optoacoustic pulses as input with inherent broadband high-frequency characteristics. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER | - |
dc.title | Variable-focus optoacoustic lens with wide dynamic range and long focal length by using a flexible polymer nano-composite membrane | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Hui Joon | - |
dc.identifier.doi | 10.1016/j.ultras.2021.106545 | - |
dc.identifier.scopusid | 2-s2.0-85111503603 | - |
dc.identifier.wosid | 000711853400003 | - |
dc.identifier.bibliographicCitation | ULTRASONICS, v.117, pp.1 - 9 | - |
dc.relation.isPartOf | ULTRASONICS | - |
dc.citation.title | ULTRASONICS | - |
dc.citation.volume | 117 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 9 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Acoustics | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Acoustics | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | Acoustic impedance | - |
dc.subject.keywordPlus | Composite membranes | - |
dc.subject.keywordPlus | Acoustic cavitations | - |
dc.subject.keywordPlus | Focused ultrasound | - |
dc.subject.keywordPlus | High frequency characteristics | - |
dc.subject.keywordPlus | Long focal lengths | - |
dc.subject.keywordPlus | Nano-composite membranes | - |
dc.subject.keywordPlus | Pressure amplitudes | - |
dc.subject.keywordPlus | Shock wave treatments | - |
dc.subject.keywordPlus | Wide dynamic range | - |
dc.subject.keywordPlus | Nanocomposites | - |
dc.subject.keywordAuthor | Laser-generated focused ultrasound | - |
dc.subject.keywordAuthor | Optoacoustic lens | - |
dc.subject.keywordAuthor | Variable focus | - |
dc.subject.keywordAuthor | Laser-ultrasonic transmitter | - |
dc.subject.keywordAuthor | Liquid-filled lens | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0041624X21001724?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.