Cited 0 time in
Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, MinSeok | - |
| dc.contributor.author | Kim, Han Sung | - |
| dc.contributor.author | Yoo, Jaeryong | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Il Jang, Won | - |
| dc.contributor.author | Park, Sunhoo | - |
| dc.date.accessioned | 2022-07-06T11:11:43Z | - |
| dc.date.available | 2022-07-06T11:11:43Z | - |
| dc.date.issued | 2021-12 | - |
| dc.identifier.issn | 1738-5733 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/140267 | - |
| dc.description.abstract | The counting efficiencies obtained using anthropomorphic physical phantoms are generally used in whole-body counting measurements to determine the level of internal contamination in the body. Geometrical discrepancies between phantoms and measured individuals affect the counting efficiency, and thus, considering individual physical characteristics is crucial to improve the accuracy of activity estimates. In the present study, the counting efficiencies of whole-body counting measurements were calculated considering individual physical characteristics by employing Monte Carlo simulation for calibration. The NaI(Tl)-based stand-up and HPGe-based bed type commercial whole-body counters were used for calculating the counting efficiencies. The counting efficiencies were obtained from 19 computational phantoms representing various shapes and sizes of the measured individuals. The discrepancies in the counting efficiencies obtained using the computational and physical phantoms range from 2% to 33%, and the results indicate that the counting efficiency depends on the size of the measured individual. Taking into account the body size, the equations for estimating the counting efficiencies were derived from the relationship between the counting efficiencies and the body-build index of the subject. These equations can aid in minimizing the size dependency of the counting efficiency and provide more accurate measurements of internal contamination in whole-body counting measurements. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN NUCLEAR SOC | - |
| dc.title | Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1016/j.net.2021.06.026 | - |
| dc.identifier.scopusid | 2-s2.0-85109064392 | - |
| dc.identifier.wosid | 000697058300015 | - |
| dc.identifier.bibliographicCitation | NUCLEAR ENGINEERING AND TECHNOLOGY, v.53, no.12, pp 4122 - 4129 | - |
| dc.citation.title | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
| dc.citation.volume | 53 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 4122 | - |
| dc.citation.endPage | 4129 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002776075 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | NUCLEAR-POWER-PLANT | - |
| dc.subject.keywordPlus | COLOR SLICE IMAGES | - |
| dc.subject.keywordPlus | BOMAB PHANTOM SIZE | - |
| dc.subject.keywordPlus | FUKUSHIMA | - |
| dc.subject.keywordAuthor | Counting efficiency | - |
| dc.subject.keywordAuthor | Whole-body counter | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.subject.keywordAuthor | Computational phantom | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1738573321003478?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
