Cited 0 time in
Power Loss Analysis of Full-Bridge LLC Resonant Converter
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Choi, So-Yeon | - |
| dc.contributor.author | Kim, Rae-Young | - |
| dc.date.accessioned | 2022-07-06T11:53:45Z | - |
| dc.date.available | 2022-07-06T11:53:45Z | - |
| dc.date.issued | 2021-10 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/140647 | - |
| dc.description.abstract | In this paper, a method of modeling the power loss of a full-bridge LLC resonant converter using the TDA (Time-Domain Analysis) method is proposed. Loss analysis based on TDA has higher accuracy than that of conventional FHA-based analysis. The proposed method shows the loss of a converter whose initial value is theoretically calculated for TDA analysis for a Full-Bridge LLC resonant converter. Also, compare the simulation value with the proposed method based on the prototype of the 10kw LLC resonant converter. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IEEE | - |
| dc.title | Power Loss Analysis of Full-Bridge LLC Resonant Converter | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.23919/ICEMS52562.2021.9634186 | - |
| dc.identifier.scopusid | 2-s2.0-85123931403 | - |
| dc.identifier.wosid | 000790083500032 | - |
| dc.identifier.bibliographicCitation | 2021 24TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2021), pp 179 - 182 | - |
| dc.citation.title | 2021 24TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2021) | - |
| dc.citation.startPage | 179 | - |
| dc.citation.endPage | 182 | - |
| dc.type.docType | Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.subject.keywordPlus | Power converters | - |
| dc.subject.keywordPlus | Power electronics | - |
| dc.subject.keywordPlus | Time domain analysis | - |
| dc.subject.keywordPlus | Analysis method | - |
| dc.subject.keywordPlus | Full bridge | - |
| dc.subject.keywordPlus | High-accuracy | - |
| dc.subject.keywordPlus | LLC resonant converter | - |
| dc.subject.keywordPlus | Losses analysis | - |
| dc.subject.keywordPlus | Method of modeling | - |
| dc.subject.keywordPlus | Power loss analysis | - |
| dc.subject.keywordPlus | Powerloss | - |
| dc.subject.keywordPlus | Time-domain analysis | - |
| dc.subject.keywordAuthor | LLC Resonant Converter | - |
| dc.subject.keywordAuthor | TDA(Time-Domain Analysis) | - |
| dc.subject.keywordAuthor | Loss Analysis | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/9634186 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.