Pseudotumor Associated with Dall-Miles Cable Breakage Following Revision Total Hip Arthroplasty: A Case Report
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oh, Se Won | - |
dc.contributor.author | Jee, Seung Yun | - |
dc.contributor.author | Park, Seong Oh | - |
dc.date.accessioned | 2022-07-06T11:59:34Z | - |
dc.date.available | 2022-07-06T11:59:34Z | - |
dc.date.created | 2021-12-08 | - |
dc.date.issued | 2021-10 | - |
dc.identifier.issn | 2586-0402 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/140755 | - |
dc.description.abstract | A pseudotumor is a benign granulomatous or cystic lesion associated with the deposition of metal debris in joint arthroplasties. To the best of our knowledge, this is the first report on a pseudotumor caused by the breakage of the Dall-Miles cable grip system, a multifilament cable used to fix the trochanteric osteotomy in revision total hip arthroplasty. This rare case demonstrates that pseudotumor formation can be caused by various types of orthopedic materials and implant components. When encountering a palpable mass around an orthopedic implant, a pseudotumor should be considered along other differential diagnoses. To treat pseudotumors and also prevent recurrence, its complete resection and sufficient removal of orthopedic materials are necessary. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Korean Wound Management Society | - |
dc.title | Pseudotumor Associated with Dall-Miles Cable Breakage Following Revision Total Hip Arthroplasty: A Case Report | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Seong Oh | - |
dc.identifier.doi | 10.22467/jwmr.2021.01732 | - |
dc.identifier.scopusid | 2-s2.0-85149309148 | - |
dc.identifier.bibliographicCitation | Journal of Wound Management and Research, v.17, no.3, pp.187 - 192 | - |
dc.relation.isPartOf | Journal of Wound Management and Research | - |
dc.citation.title | Journal of Wound Management and Research | - |
dc.citation.volume | 17 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 187 | - |
dc.citation.endPage | 192 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002770357 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | Pseudotumor | - |
dc.subject.keywordAuthor | Granuloma | - |
dc.subject.keywordAuthor | Metallosis | - |
dc.subject.keywordAuthor | Dall-Miles cable grip system | - |
dc.subject.keywordAuthor | Arthroplasty | - |
dc.identifier.url | https://www.jwmr.org/journal/view.php?doi=10.22467/jwmr.2021.01732 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.