Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels

Full metadata record
DC Field Value Language
dc.contributor.authorIhn, Yon-Kwon-
dc.contributor.authorKim, Bum-soo-
dc.contributor.authorJeong, Hae Woong-
dc.contributor.authorSuh, Sang Hyun-
dc.contributor.authorWon, Yoo Dong-
dc.contributor.authorLee, Young Jun-
dc.contributor.authorKim, Dong Joon-
dc.contributor.authorJeon, Pyong-
dc.contributor.authorRyu, Chang-Woo-
dc.contributor.authorSuh, Sang-il-
dc.contributor.authorChoi, Dae Seob-
dc.contributor.authorChoi, See Sung-
dc.contributor.authorKim, Sang Heum-
dc.contributor.authorByun, Jun Soo-
dc.contributor.authorRho, Jieun-
dc.contributor.authorSong, Yunsun-
dc.contributor.authorJeong, Woo Sang-
dc.contributor.authorHong, Noah-
dc.contributor.authorBaik, Sung Hyun-
dc.contributor.authorPark, Jeong Jin-
dc.contributor.authorLim, Soo Mee-
dc.contributor.authorKim, Jung-Jae-
dc.contributor.authorYoon, Woong-
dc.date.accessioned2022-07-06T11:59:39Z-
dc.date.available2022-07-06T11:59:39Z-
dc.date.created2021-12-08-
dc.date.issued2021-10-
dc.identifier.issn2093-9043-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/140757-
dc.description.abstractPurpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL). Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution. Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group. Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs.-
dc.language영어-
dc.language.isoen-
dc.publisher대한신경중재치료의학회-
dc.titleMonitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Young Jun-
dc.identifier.doi10.5469/neuroint.2021.00437-
dc.identifier.bibliographicCitationNeurointervention, v.16, no.3, pp.240 - 251-
dc.relation.isPartOfNeurointervention-
dc.citation.titleNeurointervention-
dc.citation.volume16-
dc.citation.number3-
dc.citation.startPage240-
dc.citation.endPage251-
dc.type.rimsART-
dc.identifier.kciidART002773596-
dc.description.journalClass2-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorCerebral angiography-
dc.subject.keywordAuthorDiagnostic reference levels-
dc.subject.keywordAuthorRadiation monitoring-
dc.subject.keywordAuthorIntracranial aneurysm-
dc.subject.keywordAuthorThrombectomy-
dc.subject.keywordAuthorIntracranial arteriovenous malformation-
dc.identifier.urlhttps://neurointervention.org/journal/view.php?doi=10.5469/neuroint.2021.00437-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Young Jun photo

Lee, Young Jun
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE