Detailed Information

Cited 1 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of paediatric mesh-type reference computational phantom series of International Commission on Radiological Protection

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorShin, Bangho-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorNguyen, Thang Tat-
dc.contributor.authorHan, Haegin-
dc.contributor.authorHa, Sangseok-
dc.contributor.authorChung, Beom Sun-
dc.contributor.authorBolch, Wesley E.-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2022-07-06T14:33:35Z-
dc.date.available2022-07-06T14:33:35Z-
dc.date.created2021-11-22-
dc.date.issued2021-09-
dc.identifier.issn0952-4746-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141096-
dc.description.abstractVery recently, Task Group 103 of the International Commission on Radiological Protection (ICRP) completed the development of the paediatric mesh-type reference computational phantoms (MRCPs) comprising ten phantoms (newborn, one year-old, five year-old, ten year-old, and fifteen year-old males and females). The paediatric MRCPs address the limitations of ICRP Publication 143's paediatric reference computational phantoms, which are in voxel format, stemming from the nature of the voxel geometry and the limited voxel resolutions. The paediatric MRCPs were constructed by converting the voxel-type reference phantoms to a high-quality mesh format with substantial enhancements in the detailed anatomy of the small and complex organs and tissues (e.g. bones, lymphatic nodes, and extra-thoracic region). Besides, the paediatric MRCPs were developed in consideration of the intra-organ blood contents and by modelling the micron-thick target and source regions of the skin, lens, urinary bladder, alimentary tract organs, and respiratory tract organs prescribed by the ICRP. For external idealised exposures, the paediatric MRCPs provide very similar effective dose coefficients (DC(E)s) to those from the ICRP-143 phantoms but significantly different values for weakly penetrating radiations (e.g. the difference of similar to 20 000 times for 10 keV electron beams). This paper introduces the developed paediatric MRCPs with a brief explanation of the construction process. Then, it discusses their computational performance in Geant4, PHITS, and MCNP6 in terms of memory usage and computation speed and their impact on dose calculations by comparing their calculated values of DC(E)s for external exposures with those of the voxel-type reference phantoms.-
dc.language영어-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.titleDevelopment of paediatric mesh-type reference computational phantom series of International Commission on Radiological Protection-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1088/1361-6498/ac0801-
dc.identifier.scopusid2-s2.0-85114344880-
dc.identifier.wosid000686334400001-
dc.identifier.bibliographicCitationJournal of Radiological Protection, v.41, no.3, pp.S160 - S170-
dc.relation.isPartOfJournal of Radiological Protection-
dc.citation.titleJournal of Radiological Protection-
dc.citation.volume41-
dc.citation.number3-
dc.citation.startPageS160-
dc.citation.endPageS170-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCONVERSION-
dc.subject.keywordAuthorICRP Task Group 103-
dc.subject.keywordAuthorICRP reference phantom-
dc.subject.keywordAuthorpaediatric phantom-
dc.subject.keywordAuthormesh-type-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/1361-6498/ac0801-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE