Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Robust L Approximation of an LCL Filter Type Grid-Connected Inverter Using Active Disturbance Rejection Control under Grid Impedance Uncertainty

Full metadata record
DC Field Value Language
dc.contributor.authorSaleem, Muhammad-
dc.contributor.authorKhushik, Muhammad Hanif Ahmed Khan-
dc.contributor.authorTahir, Hira-
dc.contributor.authorKim, Rae-Young-
dc.date.accessioned2022-07-06T14:35:05Z-
dc.date.available2022-07-06T14:35:05Z-
dc.date.created2021-11-22-
dc.date.issued2021-09-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141121-
dc.description.abstractHigh-order filters, such as LCL, are more commonly employed in grid-connected inverters (GcIs) as an interference element for the better attenuation of switching harmonics. However, LCL filters may have resonance poles and antiresonance zeros in the frequency response with inverter side current. This may affect the stability of the system and limit the control bandwidth with the simple single-loop PI control. This becomes severe with the introduction of grid impedance due to the large distance between renewable energy sources and the power grid. To mitigate this effect, active damping and sensorless damping is preferred with pre-information about grid impedance. In this paper, linear active disturbance rejection control (ADRC) is introduced, first to L filter type GcI and later extended to LCL filter type GcIs with minimum modification. From the frequency analysis, it is shown that the characteristics of the proposed control scheme remain the same even with a change in filter order and grid impedance. The resonance poles and antiresonance zeros in the LCL filter are compensated via the pole-zero cancelation technique. In addition to this, the preserve bandwidth, simple control design, and decoupled current control are also achieved with the proposed method. The robustness of the proposed method is compared with the single-loop PI control under different filter types and grid impedance uncertainty through MATLAB simulation and experimental outcomes.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.titleRobust L Approximation of an LCL Filter Type Grid-Connected Inverter Using Active Disturbance Rejection Control under Grid Impedance Uncertainty-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Rae-Young-
dc.identifier.doi10.3390/en14175276-
dc.identifier.scopusid2-s2.0-85113729023-
dc.identifier.wosid000694154400001-
dc.identifier.bibliographicCitationENERGIES, v.14, no.17, pp.1 - 21-
dc.relation.isPartOfENERGIES-
dc.citation.titleENERGIES-
dc.citation.volume14-
dc.citation.number17-
dc.citation.startPage1-
dc.citation.endPage21-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusVOLTAGE FEEDFORWARD-
dc.subject.keywordPlusRESONANCE-
dc.subject.keywordPlusCONVERTERS-
dc.subject.keywordPlusOBSERVER-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordAuthoractive disturbance rejection control (ADRC)-
dc.subject.keywordAuthorextended state observer (ESO)-
dc.subject.keywordAuthorgrid-connected inverter-
dc.subject.keywordAuthorLCL filter-
dc.subject.keywordAuthorgrid impedance-
dc.subject.keywordAuthorresonance and antiresonance effect-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 전기공학전공 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Rae Young photo

Kim, Rae Young
COLLEGE OF ENGINEERING (MAJOR IN ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE