Cited 0 time in
Just noticeable difference of Lp,A,S,4m specified ISO 3382-3
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Haram | - |
| dc.contributor.author | Santika, Beta Bayu | - |
| dc.contributor.author | Jo, Hyun In | - |
| dc.contributor.author | Jeon, Jin Yong | - |
| dc.date.accessioned | 2022-07-06T14:45:23Z | - |
| dc.date.available | 2022-07-06T14:45:23Z | - |
| dc.date.created | 2021-12-08 | - |
| dc.date.issued | 2021-08 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141229 | - |
| dc.description.abstract | In this study, the sound environmental characteristics of open-plan office (OPO) were investigated, and human perception of the sound environment of OPO was also investigated in terms of the single number quantity (Lp,A,S,4m) specified in ISO 3382-3. Furthermore, a design guideline that can enhance sound environment of OPO in terms of speech-privacy and human perception has been proposed. The sound environment of two OPOs was measured and modeled by computer simulation and auditory evaluation was conducted by 37 subjects and the stimulus that the subjects heard was generated based on Lp,A,S,4m value. Just noticeable difference value of Lp,A,S,4m was evaluated based on the responses to willingness to work, annoyance, speech privacy, and adjectives describing OPO's sound environment in each stimulus. The subjects evaluated each sound environment for its expressions of adjectives, for instance, immersive, pleasant, comfortable. As a result, it was found that people response differently when the Lp,A,S,4m value changes about 3 dB(A) averagely and positive adjectives have a negative correlation with Lp,A,S,4m. It is believed that the outcome of this investigation could be utilized as basic information when we design the optimal OPO sound environment. In addition, it could be helpful for establishing the standard design criteria. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | The Institute of Noise Control Engineering of the USA, Inc. | - |
| dc.title | Just noticeable difference of Lp,A,S,4m specified ISO 3382-3 | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Jeon, Jin Yong | - |
| dc.identifier.doi | 10.3397/IN-2021-2990 | - |
| dc.identifier.scopusid | 2-s2.0-85117422759 | - |
| dc.identifier.bibliographicCitation | Proceedings of INTER-NOISE 2021 - 2021 International Congress and Exposition of Noise Control Engineering, pp.4919 - 5918 | - |
| dc.relation.isPartOf | Proceedings of INTER-NOISE 2021 - 2021 International Congress and Exposition of Noise Control Engineering | - |
| dc.citation.title | Proceedings of INTER-NOISE 2021 - 2021 International Congress and Exposition of Noise Control Engineering | - |
| dc.citation.startPage | 4919 | - |
| dc.citation.endPage | 5918 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Conference Paper | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.