Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Phase-change material-integrated thermoelectric radiant panel: Experimental performance analysis and system design

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Yong-Kwon-
dc.contributor.authorLim, Hansol-
dc.contributor.authorCheon, Seong-Yong-
dc.contributor.authorJeong, Jae-Weon-
dc.date.accessioned2022-07-06T16:27:32Z-
dc.date.available2022-07-06T16:27:32Z-
dc.date.created2021-07-14-
dc.date.issued2021-07-
dc.identifier.issn1359-4311-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/141552-
dc.description.abstractThe objective of this research was to experimentally analyze the cooling performance of a phase-change material-integrated thermoelectric radiant cooling panel (PCM–TERCP) under active and passive cooling operation modes. Empirical models were derived for the PCM–TERCP to provide the available cooling capacity, duration time, and electric power consumption of the panel for the melting period (passive cooling mode) and solidifying period (active cooling mode) under a given operating condition. In the experiments, the durations of both the active and passive cooling were extended by up to 4 h when the thickness of the PCM layer increased from 5 mm to 15 mm. The mean cooling capacities of the proposed panel under the active cooling and passive cooling modes were approximately 58 W/m2 and 54 W/m2, respectively, when the mean radiant temperature (MRT) was 26 °C. Both cooling capacities decreased under lower MRT conditions. Empirical correlations for the cooling duration, cooling capacity, and electric power consumption of the proposed panel were used as objective functions to determine the optimum PCM layer thickness. The optimum PCM thickness of the proposed panel was determined to be 6–8 mm when providing a higher weight to minimizing the electric power consumption than to maximizing the cooling capacity.-
dc.language영어-
dc.language.isoen-
dc.publisherElsevier Ltd-
dc.titlePhase-change material-integrated thermoelectric radiant panel: Experimental performance analysis and system design-
dc.typeArticle-
dc.contributor.affiliatedAuthorJeong, Jae-Weon-
dc.identifier.doi10.1016/j.applthermaleng.2021.117082-
dc.identifier.scopusid2-s2.0-85106222739-
dc.identifier.wosid000660532500039-
dc.identifier.bibliographicCitationApplied Thermal Engineering, v.194, pp.1 - 13-
dc.relation.isPartOfApplied Thermal Engineering-
dc.citation.titleApplied Thermal Engineering-
dc.citation.volume194-
dc.citation.startPage1-
dc.citation.endPage13-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.subject.keywordPlusENERGY EFFICIENCY CENTER-
dc.subject.keywordPlusPCM COOLING CEILINGS-
dc.subject.keywordAuthorCeiling radiant cooling panel-
dc.subject.keywordAuthorPhase-change material-
dc.subject.keywordAuthorThermal storage-
dc.subject.keywordAuthorThermoelectric module-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1359431121005251?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE