Detailed Information

Cited 14 time in webofscience Cited 17 time in scopus
Metadata Downloads

Miniaturized Dual-Band Circularly Polarized Implantable Antenna for Capsule Endoscopic System

Authors
Hayat, ShahzebShah, Syed Ahson AliYoo, Hyoung suk
Issue Date
Apr-2021
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Slot antennas; Performance evaluation; Impedance; Dual band; Antenna measurements; Wireless communication; Antenna; capsule device; circular polarization; industrial; scientific; and medical (ISM) band; link budget; wireless capsule endoscopy
Citation
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, v.69, no.4, pp.1885 - 1895
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION
Volume
69
Number
4
Start Page
1885
End Page
1895
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142111
DOI
10.1109/TAP.2020.3026881
ISSN
0018-926X
Abstract
This study proposes a miniaturized dual-band antenna with a circular-polarization characteristic for a wireless-capsule endoscopic system operating in the industrial, scientific, and medical bands: 915 and 2450 MHz. The proposed capsule device is intended for deep-tissue implantation with the standard dimensions of 26 x 11 mm(2). The key features of the proposed antenna are its CP characteristic at both bands, satisfactory gain values, and a smallest volume (6.5 x 6.5 x 0.05 = 2.11 mm(3)) with a via-less ground plane compared with the state-of-the-art device. The CP wave performance and the miniaturization of the antenna are achieved via the introduction of slots accompanied by meandered line segments in a radiating patch and open-end slots in a ground plane. Furthermore, the proposed antenna offers a reasonable axial ratio (AR) of <3 dB at the desired frequency bands. The circularly polarized radiator attains the AR bandwidths (BWs) of 33.0% and 8.67% and the measured -10 dB impedance BWs of 13.63% and 6.28% at 915 and 2450 MHz, respectively. The measurements of the reflection coefficient and radiation pattern are performed using a fabricated prototype of the proposed antenna system in a saline solution and minced pork. Finally, the safety considerations and link budget calculations are evaluated to analyze the performance of the proposed capsule device. Due to the AR BW, impedance BW, and ease of fabrication, the proposed antenna system is a suitable candidate for use in endoscopic applications.
Files in This Item
Go to Link
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hyoungsuk photo

Yoo, Hyoungsuk
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)