Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Early-Phase SPECT/CT for Diagnosing Osteomyelitis: A Retrospective Pilot Study

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Soo Jin-
dc.contributor.authorWon, Kyoung Sook-
dc.contributor.authorChoi, Hyung Jin-
dc.contributor.authorChoi, Yun Young-
dc.date.accessioned2022-07-06T22:38:31Z-
dc.date.available2022-07-06T22:38:31Z-
dc.date.created2021-05-14-
dc.date.issued2021-04-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142116-
dc.description.abstractObjective: The aim of this pilot study was to investigate the potential of early-phase single-photon emission computed tomography (SPECT)/computed tomography (CT) using technetium-99m methyl diphosphonate (Tc-99m-MDP) for diagnosing osteomyelitis (OM). Materials and Methods: Twenty-one patients with suspected OM were enrolled retrospectively. Three-phase bone scan (TPBS), early-phase SPECT/CT (immediately after blood pool planar imaging), and delayed-phase SPECT/CT (immediately after delayed planar imaging) were performed. The final diagnoses were established through surgery or clinical follow-up for over 6 months. We compared three diagnostic criteria based on (I) TPBS alone, (II) combined TPBS and delayed-phase SPECT/CT, and (III) early-phase SPECT/CT alone. Results: OM was diagnosed in 11 of 21 patients (nine surgically and two clinically). Of the 11 OM patients, criterion-I, criterion-II, and criterion-III were positive in six, seven, and 10 patients, respectively. Of the 10 non-OM patients, criterion-I, criterion-II, and criterion-III were negative in five, five, and seven patients, respectively. The sensitivity/specificity/ accuracy of criterion-I, criterion-II, and criterion-III for diagnosing OM were 54.5%/50.0%/55.0%, 63.6%/50.0%/57.1%, and 90.9%/70.0%/87.5%, respectively. Conclusion: This pilot study demonstrated the potential of using the early-phase SPECT/CT to diagnose OM. Based on the results, prospective studies with a larger sample size should be conducted to confirm the efficacy of early-phase SPECT/CT.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN RADIOLOGICAL SOC-
dc.titleEarly-Phase SPECT/CT for Diagnosing Osteomyelitis: A Retrospective Pilot Study-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Yun Young-
dc.identifier.doi10.3348/kjr.2019.0746-
dc.identifier.scopusid2-s2.0-85103467531-
dc.identifier.wosid000637823500012-
dc.identifier.bibliographicCitationKorean Journal of Radiology, v.22, no.14, pp.604 - 611-
dc.relation.isPartOfKorean Journal of Radiology-
dc.citation.titleKorean Journal of Radiology-
dc.citation.volume22-
dc.citation.number14-
dc.citation.startPage604-
dc.citation.endPage611-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.identifier.kciidART002695605-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusC reactive protein-
dc.subject.keywordPlustechnetium 99m-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusaged-
dc.subject.keywordPlusankle-
dc.subject.keywordPlusArticle-
dc.subject.keywordPlusbone scintiscanning-
dc.subject.keywordPlusclinical article-
dc.subject.keywordPluscontrolled study-
dc.subject.keywordPlusdiabetic foot-
dc.subject.keywordPlusdiagnostic accuracy-
dc.subject.keywordPlusdiagnostic test accuracy study-
dc.subject.keywordPluserythrocyte sedimentation rate-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlusfollow up-
dc.subject.keywordPlusfoot-
dc.subject.keywordPlushuman-
dc.subject.keywordPlushuman tissue-
dc.subject.keywordPlusimaging-
dc.subject.keywordPlusknee-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusmiddle aged-
dc.subject.keywordPlusnuclear magnetic resonance imaging-
dc.subject.keywordPlusosteomyelitis-
dc.subject.keywordPluspilot study-
dc.subject.keywordPluspositron emission tomography-
dc.subject.keywordPluspredictive value-
dc.subject.keywordPlusretrospective study-
dc.subject.keywordPlusrheumatoid arthritis-
dc.subject.keywordPlussensitivity and specificity-
dc.subject.keywordPlussingle photon emission computed tomography-computed tomography-
dc.subject.keywordPlusskin redness-
dc.subject.keywordPlusskull-
dc.subject.keywordPlussoft tissue-
dc.subject.keywordPlusspine-
dc.subject.keywordPlussternum-
dc.subject.keywordPlussurgical technique-
dc.subject.keywordPlustibia-
dc.subject.keywordPlustibia fracture-
dc.subject.keywordPluswrist-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusaged-
dc.subject.keywordPlusdiagnostic imaging-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusimage processing-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusmiddle aged-
dc.subject.keywordPlusosteomyelitis-
dc.subject.keywordPluspilot study-
dc.subject.keywordPlusretrospective study-
dc.subject.keywordPlussensitivity and specificity-
dc.subject.keywordPlussingle photon emission computed tomography-
dc.subject.keywordPlusskull-
dc.subject.keywordPlustibia-
dc.subject.keywordPlusx-ray computed tomography-
dc.subject.keywordAuthorBone and bones-
dc.subject.keywordAuthorRadionuclide imaging-
dc.subject.keywordAuthorSingle photon emission computed tomography computed tomography-
dc.identifier.urlhttps://kjronline.org/DOIx.php?id=10.3348/kjr.2019.0746-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 핵의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Yun Young photo

Choi, Yun Young
서울 의과대학 (DEPARTMENT OF NUCLEAR MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE