Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Comparison of knife-edge and multi-slit camera for proton beam range verification by Monte Carlo simulation

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Jong Hoon-
dc.contributor.authorKim, Sung Hun-
dc.contributor.authorKu, Youngmo-
dc.contributor.authorLee, Hyun Su-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorShin, Dong Ho-
dc.contributor.authorJeong, Jong Hwi-
dc.date.accessioned2021-08-02T11:53:14Z-
dc.date.available2021-08-02T11:53:14Z-
dc.date.created2021-05-12-
dc.date.issued2019-04-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/14230-
dc.description.abstractThe mechanical-collimation imaging is the most mature technology in prompt gamma (PG) imaging which is considered the most promising technology for beam range verification in proton therapy. The purpose of the present study is to compare the performances of two mechanical-collimation PG cameras, knife-edge (KE) camera and multi-slit (MS) camera. For this, the PG cameras were modeled by Geant4 Monte Carlo code, and the performances of the cameras were compared for imaginary point and line sources and for proton beams incident on a cylindrical PMMA phantom. From the simulation results, the KE camera was found to show higher counting efficiency than the MS camera, being able to estimate the beam range even for 10(7) protons. Our results, however, confirmed that in order to estimate the beam range correctly, the KE camera should be aligned, at least approximately, to the location of the proton beam range. The MS camera was found to show lower efficiency, being able to estimate the beam range correctly only when the number of the protons is at least 10(8). For enough number of protons, however, the MS camera estimated the beam range correctly, errors being less than 1.2 mm, regardless of the location of the camera.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN NUCLEAR SOC-
dc.titleComparison of knife-edge and multi-slit camera for proton beam range verification by Monte Carlo simulation-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1016/j.net.2018.10.002-
dc.identifier.scopusid2-s2.0-85062701882-
dc.identifier.wosid000460093300023-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, v.51, no.2, pp.533 - 538-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.titleNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.volume51-
dc.citation.number2-
dc.citation.startPage533-
dc.citation.endPage538-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002438738-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordAuthorProton therapy-
dc.subject.keywordAuthorBeam range verification-
dc.subject.keywordAuthorPrompt gamma-
dc.subject.keywordAuthorKnife-edge camera-
dc.subject.keywordAuthorMulti-slit camera-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573318306430?via%3Dihub-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE