Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Use of Multiple Bacteriophage-Based Structural Color Sensors to Improve Accuracy for Discrimination of Geographical Origins of Agricultural Productsopen access

Authors
Seol, DaunJang, DaeilCha, KyungjoonOh, Jin-WooChung, Hoeil
Issue Date
Feb-2021
Publisher
MDPI
Keywords
bacteriophage-based structural color sensor; multiple color sensors; discrimination of geographical origin; garlic; onion; perilla
Citation
SENSORS, v.21, no.3, pp.1 - 17
Indexed
SCIE
SCOPUS
Journal Title
SENSORS
Volume
21
Number
3
Start Page
1
End Page
17
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142356
DOI
10.3390/s21030986
ISSN
1424-8220
Abstract
A single M13 bacteriophage color sensor was previously utilized for discriminating the geographical origins of agricultural products (garlic, onion, and perilla). The resulting discrimination accuracy was acceptable, ranging from 88.6% to 94.0%. To improve the accuracy further, the use of three separate M13 bacteriophage color sensors containing different amino acid residues providing unique individual color changes (Wild sensor: glutamic acid (E)-glycine (G)-aspartic acid (D), WHW sensor: tryptophan (W)-histidine (H)-tryptophan (W), 4E sensor: four repeating glutamic acids (E)) was proposed. This study was driven by the possibility of enhancing sample discrimination by combining mutually characteristic and complimentary RGB signals obtained from each color sensor, which resulted from dissimilar interactions of sample odors with the employed color sensors. When each color sensor was used individually, the discrimination accuracy based on support vector machine (SVM) ranged from 91.8-94.0%, 88.6-90.3%, and 89.8-92.1% for garlic, onion, and perilla samples, respectively. Accuracy improved to 98.0%, 97.5%, and 97.1%, respectively, by integrating all of the RGB signals acquired from the three color sensors. Therefore, the proposed strategy was effective for improving sample discriminability. To further examine the dissimilar responses of each color sensor to odor molecules, typical odor components in the samples (allyl disulfide, allyl methyl disulfide, and perillaldehyde) were measured using each color sensor, and differences in RGB signals were analyzed.
Files in This Item
Appears in
Collections
서울 자연과학대학 > 서울 수학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cha, Kyung Joon photo

Cha, Kyung Joon
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF MATHEMATICS)
Read more

Altmetrics

Total Views & Downloads

BROWSE