Ultra-Compact Implantable Antenna With Enhanced Performance for Leadless Cardiac Pacemaker System
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Zada, Muhammad | - |
| dc.contributor.author | Shah, Izaz Ali | - |
| dc.contributor.author | Basir, Abdul | - |
| dc.contributor.author | Yoo, Hyoung suk | - |
| dc.date.accessioned | 2022-07-07T00:57:25Z | - |
| dc.date.available | 2022-07-07T00:57:25Z | - |
| dc.date.issued | 2021-02 | - |
| dc.identifier.issn | 0018-926X | - |
| dc.identifier.issn | 1558-2221 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142358 | - |
| dc.description.abstract | Advancement in the technology of leadless cardiac pacemakers (LCPs) has led to ultracompact designs of implantable antennas. In this study, a small-sized antenna for integration with an LCP, which can be operated in the industrial, scientific, and medical (ISM) band of 2.4 GHz, is developed. The proposed antenna was constructed in a spiral shape to provide superior miniaturization, less sensitivity to body tissue variation, and low specific absorption rate (SAR) values, and avoid fabrication complexities due to its small size. The antenna with a footprint of 3 x 4 x 0.5 mm(3) was constructed on a high dielectric material, namely, Rogers RT/duroid 6010. To the best of the authors' knowledge, this is the smallest footprint with enhanced performance when compared to previous reports related to implantable antennas. In addition, the antenna was integrated with a 3-D printed LCP having dummy electronics and experimentally validated in saline solution and minced pork. The antenna sustained good impedance matching at the ISM band with a measured bandwidth of 21.88% and 15.46% with the device and without the device, respectively. Due to the smooth electric field (surface currents) over the patch, the antenna system had 270.28 and 31.04 W/kg peak SAR for 1 and 10 g of tissues, respectively, with a maximum peak gain of -25.95 dBi. We also discussed the effects of a coaxial cable and the antenna orientation on its performance. From the measured received signal strength, a stable biotelemetric link can be established between the implant and external controlling device up to a distance of 2 m. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers | - |
| dc.title | Ultra-Compact Implantable Antenna With Enhanced Performance for Leadless Cardiac Pacemaker System | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TAP.2020.3008070 | - |
| dc.identifier.scopusid | 2-s2.0-85089294056 | - |
| dc.identifier.wosid | 000615070200050 | - |
| dc.identifier.bibliographicCitation | IEEE Transactions on Antennas and Propagation, v.69, no.2, pp 1152 - 1157 | - |
| dc.citation.title | IEEE Transactions on Antennas and Propagation | - |
| dc.citation.volume | 69 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 1152 | - |
| dc.citation.endPage | 1157 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Telecommunications | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Telecommunications | - |
| dc.subject.keywordPlus | 3D printers | - |
| dc.subject.keywordPlus | Bandwidth | - |
| dc.subject.keywordPlus | Dielectric materials | - |
| dc.subject.keywordPlus | Electric fields | - |
| dc.subject.keywordPlus | Microstrip antennas | - |
| dc.subject.keywordPlus | Pacemakers | - |
| dc.subject.keywordPlus | Sensitivity analysis | - |
| dc.subject.keywordPlus | Slot antennas | - |
| dc.subject.keywordPlus | Tissue | - |
| dc.subject.keywordPlus | Antenna orientation | - |
| dc.subject.keywordPlus | Cardiac pacemakers | - |
| dc.subject.keywordPlus | Controlling devices | - |
| dc.subject.keywordPlus | High dielectric materials | - |
| dc.subject.keywordPlus | Implantable antennas | - |
| dc.subject.keywordPlus | Received signal strength | - |
| dc.subject.keywordPlus | Saline solutions | - |
| dc.subject.keywordPlus | Specific absorption | - |
| dc.subject.keywordPlus | Microwave antennas | - |
| dc.subject.keywordAuthor | Antennas | - |
| dc.subject.keywordAuthor | Antenna measurements | - |
| dc.subject.keywordAuthor | Pacemakers | - |
| dc.subject.keywordAuthor | Skin | - |
| dc.subject.keywordAuthor | Containers | - |
| dc.subject.keywordAuthor | Gain measurement | - |
| dc.subject.keywordAuthor | Heart | - |
| dc.subject.keywordAuthor | High dielectric | - |
| dc.subject.keywordAuthor | impedance matching | - |
| dc.subject.keywordAuthor | implantable antennas | - |
| dc.subject.keywordAuthor | sensitivity | - |
| dc.subject.keywordAuthor | specific absorption rate (SAR) | - |
| dc.subject.keywordAuthor | spiral shape | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/9140308 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.