Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Seungjae-
dc.contributor.authorSong, Yeongtak-
dc.contributor.authorLee, Jongshill-
dc.contributor.authorOh, Jaehoon-
dc.contributor.authorLim, Tae Ho-
dc.contributor.authorAhn, Chiwon-
dc.contributor.authorKim, In Young-
dc.date.accessioned2022-07-07T01:39:01Z-
dc.date.available2022-07-07T01:39:01Z-
dc.date.created2021-05-13-
dc.date.issued2021-01-
dc.identifier.issn2079-6374-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142464-
dc.description.abstractRecently, a smart-device-based chest compression depth (CCD) feedback system that helps ensure that chest compressions have adequate depth during cardiopulmonary resuscitation (CPR) was developed. However, no CCD feedback device has been developed for infants, and many feedback systems are inconvenient to use. In this paper, we report the development of a smart-ring-based CCD feedback device for CPR based on an inertial measurement unit, and propose a high-quality chest compression depth estimation algorithm that considers the orientation of the device. The performance of the proposed feedback system was evaluated by comparing it with a linear variable differential transformer in three CPR situations. The experimental results showed compression depth errors of 2.0 ± 1.1, 2.2 ± 0.9, and 1.4 ± 1.1 mm in the three situations. In addition, we conducted a pilot test with an adult/infant mannequin. The results of the experiments show that the proposed smart-ring-based CCD feedback system is applicable to various chest compression methods based on real CPR situations.-
dc.language영어-
dc.language.isoen-
dc.publisherNLM (Medline)-
dc.titleDevelopment of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study-
dc.typeArticle-
dc.contributor.affiliatedAuthorOh, Jaehoon-
dc.contributor.affiliatedAuthorKim, In Young-
dc.identifier.doi10.3390/bios11020035-
dc.identifier.scopusid2-s2.0-85100980101-
dc.identifier.wosid000622122700001-
dc.identifier.bibliographicCitationBiosensors, v.11, no.2, pp.1 - 13-
dc.relation.isPartOfBiosensors-
dc.citation.titleBiosensors-
dc.citation.volume11-
dc.citation.number2-
dc.citation.startPage1-
dc.citation.endPage13-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, AnalyticalNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusalgorithm-
dc.subject.keywordPlusArticle-
dc.subject.keywordPluschest compression depth-
dc.subject.keywordPlusmeasurement accuracy-
dc.subject.keywordPlusmeasurement error-
dc.subject.keywordPlusmobile health-
dc.subject.keywordPlusresuscitation-
dc.subject.keywordPlustelehealth-
dc.subject.keywordPlusfeedback system-
dc.subject.keywordPlusgenetic procedures-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusmanikin-
dc.subject.keywordPlusphysiologic monitoring-
dc.subject.keywordAuthorcardiopulmonary resuscitation-
dc.subject.keywordAuthorchest compression-
dc.subject.keywordAuthorinertial measurement units-
dc.subject.keywordAuthormobile health-
dc.subject.keywordAuthorsmart ring-
dc.identifier.urlhttps://www.mdpi.com/2079-6374/11/2/35-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles
서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jae hoon photo

Oh, Jae hoon
COLLEGE OF MEDICINE (DEPARTMENT OF EMERGENCY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE