Detailed Information

Cited 54 time in webofscience Cited 58 time in scopus
Metadata Downloads

Computer-Aided Nodule Detection and Volumetry to Reduce Variability Between Radiologists in the Interpretation of Lung Nodules at Low-Dose Screening Computed Tomography

Full metadata record
DC Field Value Language
dc.contributor.authorJeon, Kyung Nyeo-
dc.contributor.authorGoo, Jin Mo-
dc.contributor.authorLee, Chang Hyun-
dc.contributor.authorLee, Youkyung-
dc.contributor.authorChoo, Ji Yung-
dc.contributor.authorLee, Nyoung Keun-
dc.contributor.authorShim, Mi-Suk-
dc.contributor.authorLee, In Sun-
dc.contributor.authorKim, Kwang Gi-
dc.contributor.authorGierada, David S.-
dc.contributor.authorBae, Kyongtae T.-
dc.date.accessioned2022-07-07T02:46:22Z-
dc.date.available2022-07-07T02:46:22Z-
dc.date.created2021-05-11-
dc.date.issued2012-08-
dc.identifier.issn0020-9996-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/142748-
dc.description.abstractObjective: The aim of this study was to evaluate whether a computer-aided diagnosis (CAD) system improves interobserver agreement in the interpretation of lung nodules at low-dose computed tomography (CT) screening for lung cancer. Materials and Methods: Baseline low-dose screening CT examinations from 134 participants enrolled in the National Lung Screening Trial were reviewed by 7 chest radiologists. All participants consented to the use of their deidentified images for research purposes. Screening results were classified as positive when noncalcified nodules larger than 4 mm in diameter were present. Follow-up evaluation was recommended according to the nodule diameter: 4 mm or smaller, more than 4 to 8 mm, and larger than 8 mm. When multiple nodules were present, recommendations were based on the largest nodule. Readers initially assessed the nodule presence visually and measured the average nodule diameter manually. Revision of their decisions after reviewing the CAD marks and size measurement was allowed. Interobserver agreement evaluated using multirater kappa statistics was compared between initial assessment and that with CAD. Results: Multirater kappa values for the positivity of the screening results and follow-up recommendations were improved from moderate (kappa = 0.53-0.54) at initial assessment to good (kappa = 0.66-0.67) after reviewing CAD results. The average percentage of agreement between reader pairs on the positivity of screening results and follow-up recommendations per case was also increased from 77% and 72% at initial assessment to 84% and 80% with CAD, respectively. Conclusion: Computer-aided diagnosis may improve the reader agreement on the positivity of screening results and follow-up recommendations in the assessment of low-dose screening CT.-
dc.language영어-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.titleComputer-Aided Nodule Detection and Volumetry to Reduce Variability Between Radiologists in the Interpretation of Lung Nodules at Low-Dose Screening Computed Tomography-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Youkyung-
dc.identifier.doi10.1097/RLI.0b013e318250a5aa-
dc.identifier.scopusid2-s2.0-84863719166-
dc.identifier.wosid000306608500003-
dc.identifier.bibliographicCitationINVESTIGATIVE RADIOLOGY, v.47, no.8, pp.457 - 461-
dc.relation.isPartOfINVESTIGATIVE RADIOLOGY-
dc.citation.titleINVESTIGATIVE RADIOLOGY-
dc.citation.volume47-
dc.citation.number8-
dc.citation.startPage457-
dc.citation.endPage461-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusPULMONARY NODULES-
dc.subject.keywordPlusTHORACIC CT-
dc.subject.keywordPlusCHEST CT-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusINTEROBSERVER-
dc.subject.keywordPlusGUIDELINES-
dc.subject.keywordPlusSEGMENTATION-
dc.subject.keywordPlusAGREEMENT-
dc.subject.keywordPlusSURVIVAL-
dc.subject.keywordAuthorcomputer-aided diagnosis (CAD)-
dc.subject.keywordAuthorlung nodule-
dc.subject.keywordAuthorcomputed tomography-
dc.subject.keywordAuthorscreening-
dc.identifier.urlhttps://journals.lww.com/investigativeradiology/Fulltext/2012/08000/Computer_Aided_Nodule_Detection_and_Volumetry_to.4.aspx-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youkyung photo

Lee, Youkyung
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE