Cited 4 time in
Upgrade of trigger and DAQ for CsI at Belle II
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Aulchenko, V. | - |
| dc.contributor.author | Cheon, Byung Gu | - |
| dc.contributor.author | Kuzmin, A. | - |
| dc.contributor.author | Matvienko, D. | - |
| dc.contributor.author | Miyabayashi, K. | - |
| dc.contributor.author | Nakamura, I. | - |
| dc.contributor.author | Shebalin, V. | - |
| dc.contributor.author | Usov, Y. | - |
| dc.contributor.author | Zhulanov, V. | - |
| dc.date.accessioned | 2022-07-07T05:24:11Z | - |
| dc.date.available | 2022-07-07T05:24:11Z | - |
| dc.date.issued | 2014-09 | - |
| dc.identifier.issn | 1748-0221 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/143323 | - |
| dc.description.abstract | The designed luminosity of the Belle detector after its upgrade (Belle II experiment) is 40 times higher than the maximum reached before its shutdown for an upgrade. This necessitates an upgrade of the Belle DAQ system together with the upgrade of many detector's subsystems. In this paper the upgrade of the Belle Electromagnetic calorimeter (ECL) electronics is described. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Physics | - |
| dc.title | Upgrade of trigger and DAQ for CsI at Belle II | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1088/1748-0221/9/09/C09014 | - |
| dc.identifier.scopusid | 2-s2.0-84907484299 | - |
| dc.identifier.wosid | 000343281300014 | - |
| dc.identifier.bibliographicCitation | Journal of Instrumentation, v.9, no.9 | - |
| dc.citation.title | Journal of Instrumentation | - |
| dc.citation.volume | 9 | - |
| dc.citation.number | 9 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordAuthor | Digital signal processing (DSP) | - |
| dc.subject.keywordAuthor | Front-end electronics for detector readout | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.