Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The benefit of high-performance gradients on echo planar imaging for BOLD-based resting-state functional MRI

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Daehun-
dc.contributor.authorJo, Hang Joon-
dc.contributor.authorIn, Myung-Ho-
dc.contributor.authorYarach, Uten-
dc.contributor.authorMeyer, Nolan K.-
dc.contributor.authorBardwell Speltz, Lydia J.-
dc.contributor.authorGray, Erin M.-
dc.contributor.authorTrzasko, Joshua D.-
dc.contributor.authorHuston, John, III-
dc.contributor.authorBernstein, Matt A.-
dc.contributor.authorShu, Yunhong-
dc.date.accessioned2022-07-07T09:29:07Z-
dc.date.available2022-07-07T09:29:07Z-
dc.date.created2021-05-12-
dc.date.issued2020-12-
dc.identifier.issn0031-9155-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/144255-
dc.description.abstractImproved gradient performance in an MRI system reduces distortion in echo planar imaging (EPI), which has been a key imaging method for functional studies. A lightweight, low-cryogen compact 3T MRI scanner (C3T) is capable of achieving 80 mT m(-1) gradient amplitude with 700 T m(-1) s(-1) slew rate, in comparison with a conventional whole-body 3T MRI scanner (WB3T, 50 mT m(-1) with 200 T m(-1) s(-1)). We investigated benefits of the high-performance gradients in a high-spatial-resolution (1.5 mm isotropic) functional MRI study. Reduced echo spacing in the EPI pulse sequence inherently leads to less severe geometric distortion, which provided higher accuracy than with WB3T for registration between EPI and anatomical images. The cortical coverage of C3T datasets was improved by more accurate signal depiction (i.e. less dropout or pile-up). Resting-state functional analysis results showed that greater magnitude and extent in functional connectivity (FC) for the C3T than the WB3T when the selected seed region is susceptible to distortions, while the FC matrix for well-known brain networks showed little difference between the two scanners. This shows that the improved quality in EPI is particularly valuable for studying certain brain regions typically obscured by severe distortion.-
dc.language영어-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.titleThe benefit of high-performance gradients on echo planar imaging for BOLD-based resting-state functional MRI-
dc.typeArticle-
dc.contributor.affiliatedAuthorJo, Hang Joon-
dc.identifier.doi10.1088/1361-6560/abb2ec-
dc.identifier.scopusid2-s2.0-85097239207-
dc.identifier.wosid000592691200001-
dc.identifier.bibliographicCitationPHYSICS IN MEDICINE AND BIOLOGY, v.65, no.23, pp.1 - 12-
dc.relation.isPartOfPHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.titlePHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.volume65-
dc.citation.number23-
dc.citation.startPage1-
dc.citation.endPage12-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCONTRAST SENSITIVITY-
dc.subject.keywordPlusPHYSIOLOGICAL NOISE-
dc.subject.keywordPlusFMRI-
dc.subject.keywordPlusEPI-
dc.subject.keywordPlusCONNECTIVITY-
dc.subject.keywordPlusOPTIMIZATION-
dc.subject.keywordPlusENHANCEMENT-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordPlusFIELDS-
dc.subject.keywordAuthorhigh-performance gradients-
dc.subject.keywordAuthorcompact 3T-
dc.subject.keywordAuthorEPI distortion-
dc.subject.keywordAuthorfMRI-
dc.subject.keywordAuthorfunctional connectivity-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/1361-6560/abb2ec-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 생리학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jo, Hang Joon photo

Jo, Hang Joon
COLLEGE OF MEDICINE (DEPARTMENT OF PHYSIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE