Cited 0 time in
액체식 제습냉방 기반의 주거용 소형 공조시스템 개발 및 실험적 성능 평가
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이재희 | - |
| dc.contributor.author | 동혜원 | - |
| dc.contributor.author | 조혜진 | - |
| dc.contributor.author | 이수진 | - |
| dc.contributor.author | 임려화 | - |
| dc.contributor.author | 김보선 | - |
| dc.contributor.author | 배홍근 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2022-07-07T11:11:35Z | - |
| dc.date.available | 2022-07-07T11:11:35Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2020-11 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/144359 | - |
| dc.description.abstract | The purpose of this paper is to propose a small-scale heat-pump-driven liquid-desiccant (HPLD) air-conditioning system for residential buildings to remove both the sensible and latent loads. The operating strategies that can be applied to all seasons were established, and the operating performances and energy efficiencies of the proposed system were experimentally analyzed for the typical summer and winter operating modes. The proposed HPLD air-conditioning system consists of a liquid-desiccant (LD) unit for removing the latent load and a heat-pump (HP) unit for removing the sensible load. The experimental results indicated that the dehumidification rate was 5.29 kg/h, cooling capacity was 7450 W and its energy efficiency was 7.72 EER for the summer, and the humidification rate was 2.92 kg/h, heating capacity was 5075 W and its energy efficiency was 2.51 COP for the winter. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한설비공학회 | - |
| dc.title | 액체식 제습냉방 기반의 주거용 소형 공조시스템 개발 및 실험적 성능 평가 | - |
| dc.title.alternative | Design and Performance Evaluation of Heat Pump-driven Liquid Desiccant Air-conditioning System for Residential Building | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 대한설비공학회 2020 동계학술발표대회 논문집, pp.59 - 62 | - |
| dc.relation.isPartOf | 대한설비공학회 2020 동계학술발표대회 논문집 | - |
| dc.citation.title | 대한설비공학회 2020 동계학술발표대회 논문집 | - |
| dc.citation.startPage | 59 | - |
| dc.citation.endPage | 62 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | Heat pump | - |
| dc.subject.keywordAuthor | Liquid desiccant system | - |
| dc.subject.keywordAuthor | Air-conditioning system | - |
| dc.subject.keywordAuthor | Residential building | - |
| dc.subject.keywordAuthor | 히트펌프 | - |
| dc.subject.keywordAuthor | 액체식 제습시스템 | - |
| dc.subject.keywordAuthor | 공조 시스템 | - |
| dc.subject.keywordAuthor | 주거 건물 | - |
| dc.identifier.url | https://www.auric.or.kr/User/Rdoc/DocRdoc.aspx?returnVal=RD_R&dn=402579#.YRxzXN9t-Uk | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.