Detailed Information

Cited 7 time in webofscience Cited 7 time in scopus
Metadata Downloads

Accurate determination of polyethylene pellet density using transmission Raman spectroscopy

Authors
Kim, MooeungChung, HoeilJung, Young Mee
Issue Date
Nov-2011
Publisher
WILEY
Keywords
transmission Raman measurement; polyethylene pellets; density; internal inhomogeneity; sample-to-sample two-dimensional correlation
Citation
JOURNAL OF RAMAN SPECTROSCOPY, v.42, no.11, pp.1967 - 1976
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF RAMAN SPECTROSCOPY
Volume
42
Number
11
Start Page
1967
End Page
1976
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/144819
DOI
10.1002/jrs.2981
ISSN
0377-0486
Abstract
In this study, transmission Raman spectroscopy was explored for the direct measurement of the density of packed polyethylene (PE) pellets. A simple and direct transmission Raman measurement of packed, solid granules or pellet samples without pretreatment is greatly advantageous. Initially, the optimal packing thickness of PE pellets for transmission Raman measurement was determined by investigating the reproducibility of triplicate spectra collected by varying the thickness from 2 to 9 cm. Once determined, transmission Raman spectra were collected for 25 different grades of PE pellets and the partial least squares method was used to determine the sample density. The resulting accuracy was 0.00067 g.cm(-3), while that obtained using backscattering measurements was 0.00083 g.cm(-3). To investigate possible inhomogeneity within a pellet, Raman line mapping was performed over the face of a sectioned pellet and spectral variations among the mapped spectra were examined using principal component analysis. In addition, differential scanning calorimetry was performed on three samples prepared separately by cutting a pellet into left, middle, and right sections. Based on both studies, internal pellet inhomogeneity was found to be minute, but was clearly present. The correct sample representation of internally inhomogeneous PE pellets by the transmission Raman measurement eventually improved the accuracy for density determination. Finally sample-to-sample two-dimensional correlation analysis was used to further examine the origin of the improved accuracy.
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE