액체식 제습 시스템의 겨울철 가습 운전에 의한 에너지 절감 효과 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이수진 | - |
dc.contributor.author | 임한솔 | - |
dc.contributor.author | 조혜진 | - |
dc.contributor.author | 천성용 | - |
dc.contributor.author | 정재원 | - |
dc.date.accessioned | 2022-07-08T00:21:00Z | - |
dc.date.available | 2022-07-08T00:21:00Z | - |
dc.date.created | 2021-05-14 | - |
dc.date.issued | 2020-06 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/145497 | - |
dc.description.abstract | This study aimed to evaluate the energy benefits of liquid desiccant system for humidification in winter based on the regenerator process compared with direct-injection steam humidifier. The heat pump was selected as a heat source of liquid desiccant system because the heat pump can be operated for both cooling and heating by reverse cycle. The regeneration effectiveness and enthalpy effectiveness were used to estimate conditions of the process air leaving a regenerator of the liquid desiccant system. The results showed that the proposed system could save 42% primary energy consumption compared the reference system with direct-injection steam humidifier in winter. The liquid desiccant system for humidification needed low grade heat source while steam humidifier required high temperature heat source to provide the steam. The pre-heating the process air through regenerator in the proposed system is also critical to reduction in the operating energy. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한설비공학회 | - |
dc.title | 액체식 제습 시스템의 겨울철 가습 운전에 의한 에너지 절감 효과 분석 | - |
dc.title.alternative | Energy Benefits of Liquid Desiccant System for Humidification in Winter | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 정재원 | - |
dc.identifier.bibliographicCitation | 대한설비공학회 2020 하계학술발표대회 논문집, pp.883 - 886 | - |
dc.relation.isPartOf | 대한설비공학회 2020 하계학술발표대회 논문집 | - |
dc.citation.title | 대한설비공학회 2020 하계학술발표대회 논문집 | - |
dc.citation.startPage | 883 | - |
dc.citation.endPage | 886 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | Liquid desiccant system | - |
dc.subject.keywordAuthor | Humidification | - |
dc.subject.keywordAuthor | Regenerator | - |
dc.subject.keywordAuthor | Direct-injection steam humidifier | - |
dc.subject.keywordAuthor | 액체식 제습 시스템 | - |
dc.subject.keywordAuthor | 가습 | - |
dc.subject.keywordAuthor | 재생기 | - |
dc.subject.keywordAuthor | 스팀 분사형 가습기 | - |
dc.identifier.url | https://www.auric.or.kr/User/Rdoc/DocRdoc.aspx?returnVal=RD_R&dn=399084#.YRxvQt9t-Uk | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.