Detailed Information

Cited 1 time in webofscience Cited 0 time in scopus
Metadata Downloads

RPC upgrade project for CMS Phase II

Authors
Pedraza-Morales, M. I.Fagot, A.Gul, M.Roskas, C.Tytgat, M.Zaganidis, N.De Souza, S. FonsecaSantoro, A.Torres Da Silva De Araujo, F.Aleksandrov, A.Hadjiiska, R.Iaydjiev, P.Rodozov, M.Shopova, M.Sultanov, G.Dimitrov, A.Litov, L.Pavlov, B.Petkov, P.Petrov, A.Qian, S. J.Han, D.Yi, W.Avila, C.Cabrera, A.Carrillo, C.Segura, M.Aly, S.Assran, Y.Mahrous, A.Mohamed, A.Combaret, C.Gouzevitch, M.Grenier, G.Lagarde, F.Laktineh, I. B.Mathez, H.Mirabito, L.Shchablo, K.Bagaturia, I.Lomidze, D.Lomidze, I.Pant, L. M.Bhatnagar, V.Gupta, R.Kumari, R.Lohan, M.Singh, J. B.Amoozegar, V.Boghrati, B.Ghasemy, H.Malmir, S.Najafabadi, M. MohammadiAbbrescia, M.Gelmi, A.Iaselli, G.Lezki, S.Pugliese, G.Benussi, L.Bianco, S.Piccolo, D.Primavera, F.Buontempo, S.Crescenzo, A.Galati, G.Fienaga, F.Orso, I.Lista, L.Meola, S.Paolucci, P.Voevodina, E.Braghieri, A.Montagna, P.Ressegotti, M.Riccardi, C.Salvini, P.Vitulo, P.Cho, S. W.Choi, S. Y.Hong, B.Lee, K. S.Lim, J. H.Park, S. K.Goh, J.Kim, T. J.Carrillo Moreno, S.Miguel Colin, O.Vazquez Valencia, F.Bernardino, S. CarpinteyroEysermans, J.Estrada, C. UribeReyes-Almanza, R.Duran-Osuna, M. C.Ramirez-Sanchez, G.Sanchez-Hernandez, A.Rabadan-Trejo, R. I.Castilla-Valdez, H.Radi, A.Hoorani, H.Muhammad, S.Shah, M. A.Crotty, I.
Issue Date
May-2020
Publisher
IOP PUBLISHING LTD
Keywords
Resistive-plate chambers; Gaseous detectors; Particle tracking detectors (Gaseous detectors)
Citation
JOURNAL OF INSTRUMENTATION, v.15, no.5, pp.1 - 10
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF INSTRUMENTATION
Volume
15
Number
5
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/145802
DOI
10.1088/1748-0221/15/05/C05072
ISSN
1748-0221
Abstract
The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the eta coverage to ensure a reliable system for the High Luminosity Large Hadron Collider (HL-LHC) period. The Resistive Plate Chambers (RPCs) system will upgrade the off-detector electronics (called link system) of the chambers currently installed chambers and place improved RPCs (iRPCs) to cover the high pseudo-rapidity region, a challenging region for muon reconstruction in terms of background and momentum resolution. In order to find the best option for the iRPCs, an R&D program for new detectors was performed and real size prototypes have been tested in the Gamma Irradiation Facility (GIF++) at CERN. The results indicated that the technology suitable for the high background conditions is based on High Pressure Laminate (HPL) double-gap RPC. The RPC Upgrade Phase II program is planned to be ready after the Long Shutdown 3 (LS3).
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 물리학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae Jeong photo

Kim, Tae Jeong
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF PHYSICS)
Read more

Altmetrics

Total Views & Downloads

BROWSE