dc.description.abstract | Plutonium has potential applications in energy production in well-controlled nuclear reactors. Since nuclear power plants have great merit as environmentally friendly energy sources with a recyclable system, a recycling system for extracting Pu from spent fuels using suitable extractants has been proposed. Pu leakage is a potential environmental hazard, hence the need for chemical sensor development. Both extractants and chemical sensors involve metal-ligand interactions and to develop efficient extractants and chemical sensors, structural information about Pu ligands must be obtained by quantum calculations. Herein, six representative nitrogen tridentate ligands were introduced, and their binding stabilities were evaluated. The tridentate L6, which contains tri-pyridine chelate with benzene connectors, showed the highest binding energies for Pu(IV) and PuO2(VI) in water. Analysis based on the quantum theory of atoms in molecular analysis, including natural population analysis and electron density studies, provided insight into the bonding characteristics for each structure. We propose that differences in ionic bonding characteristics account for the Pu-ligand stability differences. These results form a basis for designing novel extractants and organic Pu sensors. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.title | Prediction of Binding Stability of Pu(IV) and PuO2(VI) by Nitrogen Tridentate Ligands in Aqueous Solution | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Bae, Sungchul | - |
dc.identifier.doi | 10.3390/ijms21082791 | - |
dc.identifier.scopusid | 2-s2.0-85083872706 | - |
dc.identifier.wosid | 000535565300133 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, v.21, no.8, pp.1 - 8 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES | - |
dc.citation.title | INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES | - |
dc.citation.volume | 21 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 8 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Biochemistry & Molecular Biology | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.subject.keywordPlus | SOLVENT-EXTRACTION | - |
dc.subject.keywordPlus | MINOR ACTINIDES | - |
dc.subject.keywordPlus | PLUTONIUM | - |
dc.subject.keywordPlus | SEPARATION | - |
dc.subject.keywordPlus | COMPLEXES | - |
dc.subject.keywordPlus | LANTHANIDE | - |
dc.subject.keywordPlus | NEPTUNIUM | - |
dc.subject.keywordPlus | CHEMISTRY | - |
dc.subject.keywordPlus | PROPOSAL | - |
dc.subject.keywordPlus | WASTES | - |
dc.subject.keywordAuthor | plutonium | - |
dc.subject.keywordAuthor | extractant | - |
dc.subject.keywordAuthor | tridentate | - |
dc.subject.keywordAuthor | sensor | - |
dc.subject.keywordAuthor | complexation | - |
dc.identifier.url | https://www.mdpi.com/1422-0067/21/8/2791 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.