Detailed Information

Cited 2 time in webofscience Cited 0 time in scopus
Metadata Downloads

Energy Performance Comparison between Two Liquid Desiccant and Evaporative Cooling-Assisted Air Conditioning Systems

Full metadata record
DC Field Value Language
dc.contributor.authorLiu, Su-
dc.contributor.authorJeong, Jae-Weon-
dc.date.accessioned2022-07-08T14:06:35Z-
dc.date.available2022-07-08T14:06:35Z-
dc.date.created2021-05-12-
dc.date.issued2020-02-
dc.identifier.issn1996-1073-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/146222-
dc.description.abstractThis study investigated the annual energy saving potential and system performance of two different evaporative cooling-based liquid desiccant and evaporative cooling-assisted air conditioning systems. One system used an indirect and direct evaporative cooler with a two-stage package to match the target supply air point. The other was equipped with a single-stage, packaged dew-point evaporative cooler that used a portion of the process air, which had been dehumidified in advance. Systems installed with the two evaporative coolers were compared to determine which one was more energy efficient and which one could provide better thermal comfort for building occupants in a given climate zone, using detailed simulation data. The detailed energy consumption data of these two systems were estimated using an engineering equation solver with each component model. The results showed that the liquid desiccant and dew-point evaporative-cooler-assisted 100% outdoor air system (LDEOAS) resulted in approximately 34% more annual primary energy consumption than that of the liquid desiccant and the indirect and direct evaporative-cooler-assisted 100% outdoor air system (LDIDECOAS). However, the LDEOAS could provide drier and cooler supply air, compared with the LDIDECOAS. In conclusion, LDIDECOAS has a higher energy saving potential than LDEOAS, with an acceptable level of thermal comfort.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.titleEnergy Performance Comparison between Two Liquid Desiccant and Evaporative Cooling-Assisted Air Conditioning Systems-
dc.typeArticle-
dc.contributor.affiliatedAuthorJeong, Jae-Weon-
dc.identifier.doi10.3390/en13030522-
dc.identifier.scopusid2-s2.0-85078953003-
dc.identifier.wosid000522489000016-
dc.identifier.bibliographicCitationENERGIES, v.13, no.3, pp.1 - 22-
dc.relation.isPartOfENERGIES-
dc.citation.titleENERGIES-
dc.citation.volume13-
dc.citation.number3-
dc.citation.startPage1-
dc.citation.endPage22-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusHEAT-PUMP DRIVEN-
dc.subject.keywordPlusDEHUMIDIFICATION-
dc.subject.keywordPlusTECHNOLOGY-
dc.subject.keywordAuthorliquid desiccant system-
dc.subject.keywordAuthorenergy simulation-
dc.subject.keywordAuthordew point indirect evaporative cooler-
dc.subject.keywordAuthorevaporative cooler-
dc.identifier.urlhttps://www.mdpi.com/1996-1073/13/3/522-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE