Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A novel visual ranking system based on arterial spin labeling perfusion imaging for evaluating perfusion disturbance in patients with ischemic strokeopen access

Authors
Lee, SangjoonPark, Dong WooKim, Tae YoonKim, Dong SunLee, Ji YoungLee, Young JunKim, Chun Ki
Issue Date
Jan-2020
Publisher
PUBLIC LIBRARY SCIENCE
Citation
PLOS ONE, v.15, no.1, pp.1 - 14
Indexed
SCIE
SCOPUS
Journal Title
PLOS ONE
Volume
15
Number
1
Start Page
1
End Page
14
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/146404
DOI
10.1371/journal.pone.0227747
ISSN
1932-6203
Abstract
We developed a visual ranking system by combining the parenchymal perfusion deficits (PPD) and hyperintense vessel signals (HVS) on arterial spin labeling (ASL) imaging. This study aimed to assess the performance of this ranking system by correlating with subtypes classified based on dynamic susceptibility contrast (DSC) imaging for evaluating the perfusion disturbance observed in patients with ischemic stroke. 32 patients with acute or subacute infarcts detected by DSC imaging were reviewed. Each patient's brain was divided into 12 areas. ASL ranks were defined by the presence (+) or absence (-) of PPD/HVS as follows; I:-/-, II:-/+, III: +/+, and IV: +/-. DSC imaging findings were categorized based on cerebral blood flow (CBF) and time to peak (TTP) as normal (normal CBF/TTP), mis-matched (normal CBF/delayed TTP), and matched (decreased CBF/delayed TTP). Two reviewers rated perfusion abnormalities in the total of 384 areas. The four ASL ranks correlated well with the DSC subtypes (Spearman's r = 0.82). The performance of ASL ranking system was excellent as indicated by the area under the curve value of 0.94 using either matched or mismatched DSC subtype as the gold standard and 0.97 using only the matched DSC subtype as the gold standard. The two methods were in good-to-excellent agreement (maximum kappa-values, 0.86). Inter-observer agreement was excellent (kappa-value, 0.98). Although the number of patients was small and the number of dropouts was high, our proposed, ASL-based visual ranking system represented by PPD and HVS provides good, graded estimates of perfusion disturbance that agree well with those obtained by DSC perfusion imaging.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Young Jun photo

Lee, Young Jun
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE