Cited 0 time in
Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jo, Young-Hoon | - |
| dc.contributor.author | Lee, Seung Gun | - |
| dc.contributor.author | Kook, Incheol | - |
| dc.contributor.author | Lee, Bong Gun | - |
| dc.date.accessioned | 2022-07-08T20:21:16Z | - |
| dc.date.available | 2022-07-08T20:21:16Z | - |
| dc.date.created | 2021-05-11 | - |
| dc.date.issued | 2020 | - |
| dc.identifier.issn | 1226-9344 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/146539 | - |
| dc.description.abstract | Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | 대한견주관절학회 | - |
| dc.title | Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Jo, Young-Hoon | - |
| dc.contributor.affiliatedAuthor | Lee, Bong Gun | - |
| dc.identifier.doi | 10.5397/cise.2020.00213 | - |
| dc.identifier.bibliographicCitation | 대한 견주관절 학회지, v.23, no.3, pp.152 - 155 | - |
| dc.relation.isPartOf | 대한 견주관절 학회지 | - |
| dc.citation.title | 대한 견주관절 학회지 | - |
| dc.citation.volume | 23 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 152 | - |
| dc.citation.endPage | 155 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART002620683 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Revision total elbow replacement surgery | - |
| dc.subject.keywordAuthor | Periprosthetic fracture | - |
| dc.subject.keywordAuthor | Allogenous strut bone graft | - |
| dc.subject.keywordAuthor | Intramedullary fixation | - |
| dc.identifier.url | https://www.cisejournal.org/journal/view.php?doi=10.5397/cise.2020.00213 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
