Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The Effect of Propofol Injection Pain on Auditory Evoked Potential Index and Bispectral Index

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Sang Yun-
dc.contributor.authorLee, Chang Wook-
dc.contributor.authorPark, Hyeong Joon-
dc.contributor.authorJeon, Woo Jae-
dc.date.accessioned2022-07-08T20:23:07Z-
dc.date.available2022-07-08T20:23:07Z-
dc.date.created2021-05-13-
dc.date.issued2019-12-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/146576-
dc.description.abstractBackground: The electroencephalogram (EEG) methods are being used widely, to monitor of the depth of awareness. Among them, auditory evoked potential (AEP index) and the bispectral index (BIS) were adopted as specific EEG methods in many clinics. We evaluated the effect of propofol injection pain on AEP index and BIS in mildly sedated patients with midazolam who undergo general anesthesia. Methods: 38 patients (18 to 65 age, ASA I or II grade) were separated in two groups randomly (group AEP and group BIS). Atropine 0.5 mg and midazolam 0.05 mg/kg were intramuscular injected as a premedication before going to operating room. Anesthesia was induced with propofol by target-controlled infusion. We had checked AEP index and BIS every 10 s till 90 s after propofol injection began. Results: With propofol injection pain, BIS was not increased, but decreased at 70, 80 and 90 s. Whereas AEP index was increased significantly at 30, 40 and 50 s, and decreased significantly after that. Conclusions: AEP index is more sensitive and reliable method to monitor depth of awareness during anesthesia induction phase in real time.-
dc.language영어-
dc.language.isoen-
dc.publishersci technol-
dc.titleThe Effect of Propofol Injection Pain on Auditory Evoked Potential Index and Bispectral Index-
dc.typeArticle-
dc.contributor.affiliatedAuthorCho, Sang Yun-
dc.identifier.bibliographicCitationAnalgesia&Resuscitation:current research, v.8, no.1, pp.1 - 3-
dc.relation.isPartOfAnalgesia&Resuscitation:current research-
dc.citation.titleAnalgesia&Resuscitation:current research-
dc.citation.volume8-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage3-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorAnesthesia-
dc.subject.keywordAuthorPropofol injection pain-
dc.subject.keywordAuthorConsciousness monitors-
dc.subject.keywordAuthorAuditory evoked potential-
dc.subject.keywordAuthorBispectral index monitor-
dc.identifier.urlhttps://www.scitechnol.com/peer-review/the-effect-of-propofol-injection-pain-on-auditory-evoked-potential-index-and-bispectral-index-EGWU.php?article_id=7882-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Sang Yun photo

Cho, Sang Yun
서울 의과대학 (DEPARTMENT OF ANESTHESIA AND MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE