Cited 0 time in
Implication of Fiber Distance on Pullout Behaviors of Steel Fibers in UHPC Under Impact Loads
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, J. | - |
| dc.contributor.author | Yoo, Doo Yeol | - |
| dc.date.accessioned | 2022-07-09T07:29:52Z | - |
| dc.date.available | 2022-07-09T07:29:52Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2019-09 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/147116 | - |
| dc.description.abstract | Fiber pullout tests provide information for a deeper understanding of the fiber behavior in fiber reinforced cementitious materials. This study examines the effects of the distance between fibers and geometry on the dynamic pullout behavior of steel fibers embedded in ultra-high-performance concrete (UHPC). To achieve this, three different geometries of steel fibers (straight, hooked, and twisted), four different distances between fibers (corresponding to fiber volume fractions of 1%, 2%, and 7% and a fiber bundle), and three different loading rates (static, 4, and 8 kN load) ranging from 0.018mm/s to 740.3 mm/s were considered. The test results indicate that the single straight fibers exhibit the most sensitive according to loading rate and get a largest load capacity dynamic increase factor (DIF), the DIFs are generally less for hooked, and twisted fiber. In multiple fibers specimen test, the straight and hooked fibers showed that the DIFs generally increased according to loading rate. However, as the distance between hooked fibers decreases, the matrix tends to be broken during the fiber pullout test and the DIF decreases. Multiple twisted fibers specimen exhibited the less sensitive response to loading rate compared to single twisted fiber test, and this is because the increased matrix spalling which deteriorate the load capacity of fiber pullout. However, the fiber bundle has an increased stiffness due to an increase of cross-sectional area, DIFs for deformed fibers bundle specimens increased notably even more than that of single fiber specimens. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | University of British Columbia | - |
| dc.title | Implication of Fiber Distance on Pullout Behaviors of Steel Fibers in UHPC Under Impact Loads | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Yoo, Doo Yeol | - |
| dc.identifier.bibliographicCitation | 7th International Colloquium on Performance, Protection and Strengthening of Structures Under Extreme Loading and Events (PROTECT 2019), pp.1 - 10 | - |
| dc.relation.isPartOf | 7th International Colloquium on Performance, Protection and Strengthening of Structures Under Extreme Loading and Events (PROTECT 2019) | - |
| dc.citation.title | 7th International Colloquium on Performance, Protection and Strengthening of Structures Under Extreme Loading and Events (PROTECT 2019) | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 10 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.identifier.url | https://docplayer.net/154445028-7th-international-colloquium-on-performance-protections-strengthening-of-structures-under-extreme-loading-events-final-program.html | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.