Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison Study of Partial Least Squares Regression Analysis and Principal Component Analysis in Fast-Scan Cyclic Voltammetry

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jaekyung-
dc.contributor.authorOh, Yoonbae-
dc.contributor.authorPark, Cheonho-
dc.contributor.authorKang, Yu Min-
dc.contributor.authorShin, Hojin-
dc.contributor.authorKim, In Young-
dc.contributor.authorJang, Dong Pyo-
dc.date.accessioned2022-07-09T11:59:59Z-
dc.date.available2022-07-09T11:59:59Z-
dc.date.created2021-05-12-
dc.date.issued2019-07-
dc.identifier.issn1452-3981-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/147467-
dc.description.abstractBoth principal component regression (PCR) and partial least squares regression (PLSR) have been commonly used to predict neurochemical concentrations from measurements of fast-scan cyclic voltammetry (FSCV). However, a comparison of the accuracy of the above methods for FSCV analysis is yet to be demonstrated. In this work, we compare the concentration estimation performance of PCR and PLSR in an analysis of FSCV data. Using conventional FSCV, we recorded in vitro background-subtracted cyclic voltammograms from five neurochemicals i.e., dopamine, ascorbic acid, 3,4-dihydroxyphenylacetic acid, and serotonin, and pH change, with five concentrations of each substance and five pH values. The results showed that the absolute error (AE) and mean absolute percentage error (MAPE) were significantly smaller on average when the concentration of a single substance was predicted using PLSR compared with the use of PCR. As a further evaluation of PCR and PLSR, we compared the predictions of the concentrations of mixtures using PCR and PLSR. The AE and MAPE in the predictions obtained using PLSR were significantly smaller than those obtained using PCR. Across the single substance and the four types of mixtures, compared with PCR, PLSR showed not only higher accuracy in the prediction of concentrations but also higher selectivity. Therefore, PLSR should be preferred over PCR as a more reliable tool to analyze FSCV data.-
dc.language영어-
dc.language.isoen-
dc.publisherESG-
dc.titleComparison Study of Partial Least Squares Regression Analysis and Principal Component Analysis in Fast-Scan Cyclic Voltammetry-
dc.typeArticle-
dc.contributor.affiliatedAuthorJang, Dong Pyo-
dc.identifier.doi10.20964/2019.07.03-
dc.identifier.scopusid2-s2.0-85071719385-
dc.identifier.wosid000474380600001-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, v.14, no.7, pp.5924 - 5937-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE-
dc.citation.titleINTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE-
dc.citation.volume14-
dc.citation.number7-
dc.citation.startPage5924-
dc.citation.endPage5937-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.subject.keywordPlusPREFRONTAL CORTEX-
dc.subject.keywordPlusWAVE-FORM-
dc.subject.keywordPlusDOPAMINE-
dc.subject.keywordAuthorFast-scan cyclic voltammetry (FSCV)-
dc.subject.keywordAuthorPrincipal component analysis (PCR)-
dc.subject.keywordAuthorPartial least squares regression (PLSR)-
dc.subject.keywordAuthorNeurochemical-
dc.identifier.urlhttp://www.electrochemsci.org/abstracts/vol14/140705924.pdf-
Files in This Item
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE