Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Response Scales as Measures of Indoor Environmental Perception in Combined Thermal and Acoustic Conditions

Full metadata record
DC Field Value Language
dc.contributor.authorYang, Wonyoung-
dc.contributor.authorMoon, Hyeun Jun-
dc.contributor.authorJeon, Jin Yong-
dc.date.accessioned2022-07-09T12:22:40Z-
dc.date.available2022-07-09T12:22:40Z-
dc.date.created2021-05-12-
dc.date.issued2019-07-
dc.identifier.issn2071-1050-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/147486-
dc.description.abstractResponse scales are widely used to assess the personal experience of sensation and perception in built environments, and have a great impact on the quality of the responses. The purpose of this study was to investigate the effects of response scales on human sensation and perception in moderate indoor environments. Four different response scales were compared under three room temperatures (19.0 degrees C, 24.5 degrees C, and 30.0 degrees C) and five acoustic stimuli (ambient noise, 42 and 61 dBA x water sounds and traffic noise): a bipolar seven-point scale according to ISO 10551:1995, a unipolar 11-point scale according to ISO/TS 15666:2003, these two scales combined for each sensory comfort assessment, and a bipolar visual analogue scale. The degree of relative differentiation based on indoor physical factors made no significant difference across the four response scales. Therefore, the effects of physical factors on human response could be assessed by using any of the four scales tested in this study, with a statistical significance at p < 0.05 in moderate environments. The choice of response scale would depend not only on the type of physical stimulus but also on the question of sensation or perception. The reliability of each response scale was different according to the subjective attributes. The bipolar visual analogue scale was subjectively preferred by the respondents.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.titleComparison of Response Scales as Measures of Indoor Environmental Perception in Combined Thermal and Acoustic Conditions-
dc.typeArticle-
dc.contributor.affiliatedAuthorJeon, Jin Yong-
dc.identifier.doi10.3390/su11143975-
dc.identifier.scopusid2-s2.0-85073894445-
dc.identifier.wosid000482261800219-
dc.identifier.bibliographicCitationSUSTAINABILITY, v.11, no.14, pp.1 - 26-
dc.relation.isPartOfSUSTAINABILITY-
dc.citation.titleSUSTAINABILITY-
dc.citation.volume11-
dc.citation.number14-
dc.citation.startPage1-
dc.citation.endPage26-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassssci-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalWebOfScienceCategoryGreen & Sustainable Science & Technology-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryEnvironmental Studies-
dc.subject.keywordPlusVISUAL ANALOG SCALES-
dc.subject.keywordPlusGREEN OFFICE BUILDINGS-
dc.subject.keywordPlusRATING-SCALES-
dc.subject.keywordPlusOCCUPANT COMFORT-
dc.subject.keywordPlusPAIN INTENSITY-
dc.subject.keywordPlusGLOBAL COMFORT-
dc.subject.keywordPlusQUALITY IEQ-
dc.subject.keywordPlusSATISFACTION-
dc.subject.keywordPlusMODEL-
dc.subject.keywordPlusTEMPERATURE-
dc.subject.keywordAuthorresponse scales-
dc.subject.keywordAuthorvisual analogue scale-
dc.subject.keywordAuthorseven-point scale-
dc.subject.keywordAuthor11-point scale-
dc.subject.keywordAuthorrespondent preference-
dc.subject.keywordAuthorthermal comfort-
dc.subject.keywordAuthoracoustic comfort-
dc.subject.keywordAuthorindoor environmental comfort-
dc.subject.keywordAuthorsensation-
dc.subject.keywordAuthorperception-
dc.identifier.urlhttps://www.mdpi.com/2071-1050/11/14/3975-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Jin Yong photo

Jeon, Jin Yong
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE