Hyperspectral Raman Line Mapping as an Effective Tool To Monitor the Coating Thickness of Pharmaceutical Tablets

Full metadata record
DC Field Value Language
dc.contributor.authorSong, Si Won-
dc.contributor.authorKim, Jaejin-
dc.contributor.authorEum, Changhwan-
dc.contributor.authorCho, Youngho-
dc.contributor.authorPark, Chan Ryang-
dc.contributor.authorWoo, Young-Ah-
dc.contributor.authorKim, Hyung Min-
dc.contributor.authorChung, Hoeil-
dc.date.accessioned2022-07-09T15:28:50Z-
dc.date.available2022-07-09T15:28:50Z-
dc.date.created2021-05-12-
dc.date.issued2019-05-
dc.identifier.issn0003-2700-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/147895-
dc.description.abstractProtective chemical coatings are deposited on drugs during the manufacturing process for the purpose of controlling the pharmacokinetics of active pharmaceutical ingredients (APIs). Although manufacturers attempt to coat all the tablets uniformly, the film thickness of an individual drug is statistically different and depends on the measuring position of the anisotropic structure, and analytical methods for measuring coating thickness must be robust to statistical and geometrical aberrations. Herein, we demonstrate that a spatially offset Raman-spectroscopy-based line mapping method offered excellent calibration and prediction of the coating thickness of 270 acetaminophen (N-acetyl-para-aminophenol, paracetamol) tablets. Raman-scattered light resurfaced back from the coating and APIs, and offset-resolved spectra were projected according to the vertical positions in an imaging sensor. The Raman intensity ratio between the coating substance and the inner APIs is a key parameter in the analysis, and its variation with respect to the spatial offset is proportional to the coating thickness and duration. The results of this study have implications for the rapid spectroscopic thickness measurement of industrial products coated with transparent or translucent materials.-
dc.language영어-
dc.language.isoen-
dc.publisherAMER CHEMICAL SOC-
dc.titleHyperspectral Raman Line Mapping as an Effective Tool To Monitor the Coating Thickness of Pharmaceutical Tablets-
dc.typeArticle-
dc.contributor.affiliatedAuthorChung, Hoeil-
dc.identifier.doi10.1021/acs.analchem.9b00047-
dc.identifier.scopusid2-s2.0-85065426130-
dc.identifier.wosid000467642100049-
dc.identifier.bibliographicCitationANALYTICAL CHEMISTRY, v.91, no.9, pp.5810 - 5816-
dc.relation.isPartOfANALYTICAL CHEMISTRY-
dc.citation.titleANALYTICAL CHEMISTRY-
dc.citation.volume91-
dc.citation.number9-
dc.citation.startPage5810-
dc.citation.endPage5816-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusQUANTITATIVE-ANALYSIS-
dc.subject.keywordPlusCOATED TABLET-
dc.subject.keywordPlusSPECTROSCOPY-
dc.identifier.urlhttps://pubs.acs.org/doi/10.1021/acs.analchem.9b00047-
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE